Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 24 (2001), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: WEBER, M., et al.: Antitachycardia Pacing for Rapid VT During ICD Charging: A Method to Prevent ICD Shocks. In patients with ICDs, rapid VTs are usually treated with shocks. It is unknown, if antitachycardia pacing (ATP) delivered once for rapid VT during capacitor charging can avoid painful shocks without increasing the risk of syncope. In patients in whom rapid monomorphic VT (cycle length 300–220 ms) could be reproducibly induced during predischarge ICD testing, the success of cardioversion (defibrillation threshold plus 10 J) and a single ATP attempt (burst with 8 or 16 stimuli) was compared using a randomized crossover study design. Consciousness of the patients was checked by the signal from a button constantly pushed by the patient. In 20 patients (ejection fraction 0.50 ± 0.19) rapid VTs (253 ± 26 ms) were reproducibly induced. A single burst successfully terminated 11 (55%) of 20 rapid VTs, 6 episodes could not be terminated with a single burst pacing and 3 VTs accelerated. Rapid VTs not terminated by ATP were significantly faster than those that could be terminated (246 vs 258 ms, P = 0.026). Cardioversion (19 ± 3 J) terminated the VTs in all cases. No patient suffered syncope during rapid VTs. A single ATP may terminate rapid VT with cycle lengths 〈 300 ms in 55% of patients without increasing the risk of syncope. Therefore, in rapid VTs one attempt of ATP may be suitable as an additional therapy option during ICD capacitor charging to avoid painful shocks without compromise of safety. Thus, future ICDs should implement the option of ATP during charging of capacitors.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1435-1285
    Subject(s): Key words Implantable cardioverter defibrillator — ICD-test — antiarrhythmic drug — ICD-dysfunction — defibrillation ; Schlüsselwörter Implantierbarer Kardioverter/Defibrillator — ICD-Test — Antiarrhythmika — ICD-Dysfunktion — Defibrillation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Postoperative tests of implantable cardioverter defibrillators (ICDs) are routinely performed to ensure appropriate defibrillation by the device. However, efficacy and complications of this procedure are unknown. To scrutinize the currently accepted indications to test the defibrillation function of the ICD we retrospectively analyzed 844 ICD-tests in 439 ICD-systems and 409 patients. 755 ICD-tests (89.4%) were routinely performed (57% before discharge and 43% during follow-up); 58 tests (6.9%) were performed after a change of the antiarrhythmic drug regimen, 24 tests (2.9%) after a revision of a part of the ICD-system, and seven tests (0.8%) because of a suspected dysfunction of the ICD. During routine-tests six ICD-systems (0.8%) failed to defibrillate the patient. However, in all but one test abnornmalities of the ICD-system had been observed before the test. After addition of antiarrhythmic drugs, three of 58 ICD-systems (5.2%) failed to defibrillate the patient during the test (amiodarone: n = 2, flecainide: n = 1). Four of seven ICD-systems (57%) tested due to a suspected dysfunction failed to defibrillate the patient. After revisions of parts of the ICD-system, ICD-tests never revealed a failure of defibrillation. During 16 ICD-tests (1.9%) complications occurred. The most frequent complication was inaoppropriate shocks ( n = 19; 1.2 %), the most severe one (transient) neurologic symptoms (n = 4; 0.48%). Our experience demonstrates that postoperative tests of the defibrillation function of ICDs rarely reveal ICD-dysfunction. As testing is unpleasant for the patient and not free of complications, tests might be restricted to those patients in whom an ICD-dysfunction is supected (based on clinical presentation, results of chest-x-ray, testing of sensing signal and stimulation threshold) or class I or class III antiarrhythmic drugs have been added to the antiarrhythmic drug regimen.
    Notes: Zusammenfassung Der Nutzen einer postoperativ routinemäßig durchgeführten Überprüfung der Defibrillationsfunktion implantierbarer Kardioverter/Defibrillatoren (ICDs) ist unklar. Um die Indikationen zu diesen den Patienten belastenden Untersuchungen zu überprüfen, analysierten wir retrospektiv 844 ICD-Teste bei 439 Systemen und 409 Patienten. 755 ICD-Teste (89,4%) waren routinemäßig (57 % vor Entlassung; 43% während der Nachverfolgung) durchgeführt worden. Außerplanmäßig erfolgten 58 ICD-Teste (6,9%) nach Aufsättigung mit einem Antiarrhythmikum und 24 ICD-Teste (2,9%) nach Austausch oder Revision einer Komponente des ICD-Systems. Sieben ICD-Teste (0,8 %) wurden durchgeführt, weil eine Fehlfunktion des Systems vermutet wurde. Routinemäßig durchgeführte ICD-Teste ergaben bei sechs Patienten (0,8%) eine mangelhafte Defibrillationsfunktion. Bis auf einen Patienten fanden sich bei allen jedoch bereits vor der Testung Besonderheiten, die auf einen Fehlfunktion hätten schließen lassen können. Wegen einer Änderung der Antiarrhythmika-Medikation außerplanmäßig durchgeführte ICD-Testungen ergaben bei drei von 58 Patienten (5,2%) eine mangelhafte Defibrillationsfunktion (Amiodaron: n = 2; Flecainid: n = 1). In vier von sieben Fällen (57%), in denen eine Fehlfunktion des ICD-Systems vermutet wurde, ergab die außerplanmäßige ICD-Testung eine mangelhafte Defibrillationsfunktion. Nach Revision oder Austausch einer Systemkomponente zeigte der ICD-Test stets eine effektive Defibrillation. Bei 16 ICD-Testen (1,9%) traten Komplikationen auf. Am häufigsten waren unnötige Schocks (n = 10; 1,2 %). Am schwerwiegendsten waren passagere neurologische Symptome bei vier Patienten (0,48%). Somit führen postoperative Überprüfungen der Defibrillationsfunktion implantierter Defibrillatoren selten zu therapierelevanten Erkenntnissen. Routinemäßig erscheinen die für den Patienten belastenden und nicht komplikationsfreien Tests verzichtbar, wenn nach einer Überprüfung der Sensing-Signale bei Sinusrhythmus, der Schrittmacherreizschwelle und der Röntgen-Thoraxbilder keine Hinweise auf eine Systemdysfunktion bestehen und intraoperativ eine Defibrillationsschwelle mit einem ausreichenden Sicherheitsabstand bestand. Nach Aufsättigung mit einem Klasse-1- oder Klasse-III-Antiarrhythmikum sollte die Defibrillationsfunktion durch einen erneuten Test sichergestellt werden.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Zeitschrift für Kardiologie 88 (1999), S. S036 
    ISSN: 1435-1285
    Subject(s): Key words Arrhythmia – amiodarone – defibrillator – antiarrhythmic drug therapy – electrical therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Sudden death accounts for a significant proportion of all death in patients with heart failure. Of currently available therapy, amiodarone and the implantable defibrillator (ICD) appear to have the greatest potential to reduce sudden death in heart failure. In this paper, the currently available information on the relative role of amiodarone and implantable defibrillators (ICD) in heart failure is reviewed.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1435-1285
    Subject(s): Key words Implantable defibrillator – enhanced detection criteria – morphology – stability – sudden onset ; Schlüsselwörter Implantierbarer Defibrillator – Detektionskriterien – Morphologie – Stabilität – Sudden Onset
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Inadäquate Therapien implantierbarer Kardioverter-Defibrillatoren infolge supraventrikulärer Tachykardien stellen weiterhin die häufigste Komplikation der ICD-Therapie dar. Die Einführung des Morphologie (MD)-Kriteriums verspricht eine Verbesserung der Spezifität in der Tachyarrhythmieerkennung bei Erhalt der Sensitivität. Ziel dieser multizentrischen Studie war die systematische Analyse von Sensitivität und Spezifität des MD-Kriteriums in kombinierter Anwendung mit den Kriterien Stabilität und Frequenzsprung (Sudden Onset) bei spontanen Episoden ventrikulärer und supraventrikulärer Tachykardien. Bei 259 Patienten wurden nach ICD-Implantation 787 gespeicherte Episoden bei 74 Patienten mit erhältlichem Speicherelektrogramm während einer Nachbeobachtungszeit von 359±214 Tagen analysiert. Bei nominaler Programmierung des MD-Kriteriums mit ≥60% ergaben sich unter Berücksichtigung aller Episoden eine Sensitivität/Spezifität der Detektion von 82,6%/77,2%. Bei getrennter Analyse von Sinustachykardien, Vorhofflimmern und Vorhofflattern betrug die Spezifität 80,6%, 69,6% und 75%. Bei Patienten mit primär adäquater MD-Detektion waren Sensitivität und Spezifität mit 95,8%/91,7% deutlich verbessert. Bei nominaler Programmierung des Sudden Onset-Kriteriums mit 〈100ms und des Stabilitätskriteriums mit 〈50ms ergaben sich für die Kombination MD- und Sudden-Onset-Kriterium bzw. MD- und Stabilitätskriterium eine Sensitivität/Spezifität von 96,2%/52,2% bzw. 94,4%/63,8%. Die Anwendung des MD-Detektionskriteriums lässt in der kombinierten Anwendung mit den herkömmlichen erweiterten Kriterien wie Sudden Onset- und Stabilitätskriterien eine deutlich verbesserte Spezifität der ICD-Therapie erwarten.
    Notes: Summary The high incidence of inappropriate therapies due to supraventricular tachycardia remains a major unsolved problem of the implantable cardioverter defibrillator. A new morphology discrimination (MD) algorithm has been introduced to improve specificity of ICD therapy without loss of sensitivity. It was the aim of this study to systematically analyze sensitivity and specificity of the MD criterion in combination with the enhanced detection criteria sudden onset and rate stability in the detection of ventricular and supraventricular tachycardia. After ICD implantation in 259 patients, 787 detected episodes in 74 patients with available stored electrograms were documented during a follow-up period of 359±214 days. With a nominal programming of the MD algorithm at ≥60%, sensitivity and specificity for all episodes were 82.6%/77.2%. For sinus tachycardia, atrial fibrillation and atrial flutter the specificities were 80.6%, 69.6% and 75%, respectively. In patients with primarily appropriate MD detection, sensitivity and specificity significantly improved to 95.8%/91.7%. Programming the sudden onset criterion with 〈100ms and the stability criterion with 〈50ms, sensitivity and stability of the combined application of the MD algorithm and sudden onset and MD algorithm and stability were 96.2%/52.2% and 94.4%/63.8%, respectively. The MD criterion in combination with other enhanced detection criteria might significantly improve specificity of tachyarryhthmia detection of ICD therapy.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Der Internist 41 (2000), S. 241-252 
    ISSN: 1432-1289
    Subject(s): Schlüsselwörter Herzrhythmusstörungen, Herzinsuffizienz ; Herzinsuffizienz, Herzrhythmusstörungen ; Amiodaron ; Sotalol ; Implantierbarer Kardioverter Defibrillator
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zum Thema Die Tatsache, daß Patienten mit Herzinsuffizienz ebenso oft an Herzrhythmusstörungen wie an kardialem Pumpversagen versterben, mag zwar verwundern, ist aber zutreffend. Diese Arbeit beschäftigt sich mit den pathophysiologischen Voraussetzungen, den klinischen Auswirkungen, der Diagnostik und – besonders eingehend – der Therapie von Herzrhythmusstörungen bei Herzinsuffizienz. Diagnostisch dominiert vor allem natürlich das Elektrokardiogramm in den verschiedenen Anwendungen als Ruhe-, Belastungs-, Langzeit- und Signal-gemitteltes EKG. Die invasive Koronarangiographie ist zur Identifizierung von Patienten mit koronarer Herzkrankheit unerläßlich, auch für therapeutische Koronarinterventionen sowie zu elektrophysiologischen Untersuchungen und ablativen Maßnahmen. Auf dem Gebiet, über das hier referiert wird, wurde in den letzten Jahren multizentrisch, national und international auf das Intensivste klinische Forschung betrieben, in die deutsche Kliniken und Institutionen eingebunden sind. Auch über die Ergebnisse dieser Studien wird ein kurzgefaßter Überblick gegeben.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1435-1544
    Subject(s): Key words Implantable cardioverter defibrillator ; Sudden cardiac death ; Children
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Implantable cardioverter defibrillators (ICDs) are the treatment of choice in adults with symptomatic ventricular tachycardia or aborted sudden cardiac death. Treatment with implantable defibrillators is also possible in children, although experience in this patient group is scanty. A review of the literature on the subject of defibrillator therapy in combination with epicardial electrodes is provided. Endocardial electrodes, which have now become the gold standard in adult treatment, have only rarely been used in children. However, our own experience shows that endocardial electrodes can be implanted in most children, which generally obviates the need for thoracotomy.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Herzschrittmachertherapie & Elektrophysiologie 9 (1998), S. S44 
    ISSN: 1435-1544
    Subject(s): Key words Implantable atrial defibrillator ; atrial fibrillation ; Schlüsselwörter Implantierbarer atrialer Defibrillator ; Vorhofflimmern
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Zur Zeit kann keine medikamentöse antiarrhythmische Therapie Rezidive von anhaltendem Vorhofflimmern und/oder die Entwicklung von permanentem, chronischem Vorhofflimmern bei einem ausreichend hohen Prozentsatz von Patienten zuverlässig vermeiden. Da Antiarrhythmika seltene, aber teilweise bedeutsame Nebenwirkungen aufweisen, wird die Behandlung von Vorhofflimmern bei vielen Patienten auf eine Kontrolle der Kammerfrequenz durch Medikamente oder Katheterablation des AV-Knotens evtl. Schrittmacherimplantation beschränkt. Stimuliert durch den Erfolg implantierbarer Cardioverter-Defibrillatoren bei der Therapie ventrikulärer Tachyarrhythmien und der hohen Effektivität der endokardialen Defibrillation von Vorhofflimmern wurden implantierbare Geräte entwickelt, die eine automatische Defibrillation von Vorhofflimmern ermöglichen. Mit solchen implantierbaren atrialen Defibrillatoren liegen erste Ergebnisse für ein selektiertes Patientengut vor. Während einer noch kurzen Nachbeobachtungsdauer konnten die Patienten durch teilweise mehrfache atriale Defibrillation im Sinusrhythmus gehalten werden. Ventrikuläre proarrhythmische Effekte wurden nicht dokumentiert. Ein nicht befriedigend gelöstes Problem, das der generellen Ausbreitung des Therapiekonzeptes entgegensteht, sind die durch die Defibrillationen hervorgerufenen Schmerzen und die Anzahl der benötigten Schocks. Bevor Indikationen für die Implantation atrialer Defibrillatoren formuliert werden können, müssen weitere Erfahrungen innerhalb von Studien vorliegen.
    Notes: Summary Currently, no therapy exists which reliably avoids recurrences of episodes of sustained atrial fibrillation and prevents the development of permanent, chronic atrial fibrillation. As antiarrhythmic drugs have rare but partly substantial side-effects, many patients are left with their atrial fibrillation and their ventricular rate can only be controlled by drugs or catheter ablation of the atrioventricular node. Due to the success of implantable cardioverter-defibrillators for ventricular tachyarrhythmias and the very effective treatment of atrial fibrillation by internal atrial defibrillation, implantable devices have been designed which can automatically defibrillate atrial fibrillation. Preliminary experience has been obtained with these devices in a few selected patients. Patients could be maintained in sinus rhythm during short-term follow-up and no ventricular proarrhythmic effects due to shock delivery were documented. However, the patients‘ tolerance of shocks and the amount of shocks needed to terminate episodes of atrial fibrillation is a major concern. Before indications for general use of implantable atrial defibrillators can be defined, further experience with such devices within studies is needed.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    facet.materialart.
    Unknown
    German Medical Science GMS Publishing House; Düsseldorf
    In:  GMS Hygiene and Infection Control; VOL: 18; DOC07 /20230327/
    Publication Date: 2023-03-27
    Description: The objective is to provide a comprehensive overview of the rapidly developing field of the current state of research on in vivo use of hypochlorous acid (HOCl) to aid infection prevention and control, including naso-pharyngeal, alveolar, topical, and systemic HOCl applications. Also, examples are provided of dedicated applications in COVID-19. A brief background of HOCl's biological and chemical specifics and its physiological role in the innate immune system is provided to understand the effect of in vivo applications in the context of the body's own physiological defense mechanisms.
    Description: Es wird ein umfassender Überblick über den aktuellen Stand der Forschung zum In-vivo-Einsatz von hypochloriger Säure (HOCl) zur Infektionsprävention und -bekämpfung gegeben. Der Schwerpunkt liegt auf nasalen, alveolären und topischen Anwendungen. Außerdem werden Beispiele für spezielle Anwendungen bei COVID-19 vorgestellt. Um die Wirkung von HOCl im Zusammenwirken mit körpereigenen physiologischen Abwehrmechanismen zu verstehen, werden die biologischen und chemischen Besonderheiten von HOCl und seiner physiologischen Rolle im humanen Immunsystem erläutert
    Subject(s): hypochlorous acid ; in vivo application ; HOCl chemistry ; innate immune response ; tissue compatibility ; infection control ; inhalation ; wound care ; disinfection ; Hypochlorige Säure ; In-vivo-Anwendung ; HOCl-Chemie ; physiologische Immunantwort ; Gewebeverträglichkei ; Infektionsprävention ; Inhalation ; Wundpflege ; Desinfektion ; ddc: 610
    Language: English
    Type: article
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...