  • 1
    ISSN: 1572-8595
    Keywords: implantable cardioverter-defibrillator ; defibrillation threshold ; defibrillation energy requirement
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Introduction: A variety of factors, including the number of defibrillation electrodes and shocking capacitance, may influence the defibrillation efficacy of an implantable defibrillator system. Therefore, the purpose of this study was to compare the defibrillation energy requirement using a 125 uF two-electrode defibrillation system and a 90 uF three-electrode defibrillation system. Methods and Results: The defibrillation energy requirements measured with both systems were compared in 26 consecutive patients. The two-electrode system used a single transvenous lead with two defibrillation coils in conjunction with a biphasic waveform from a 125 uF capacitor. The three-electrode system used the same transvenous lead, utilized a pectoral implantable defibrillator generator shell as a third electrode, and delivered the identical biphasic waveform from a 90 uF capacitor. The two-electrode system was associated with a higher defibrillation energy requirement (10.8±5.5 J) than was the three-electrode system (8.9±6.7 J, p 〈 0.05), however, the leading edge voltage was not significantly different between systems (361±103 V vs. 397±123 V, P = 0.07). The two-electrode system also had a higher shocking resistance (49.0±9.0 ohms vs. 41.4±7.3 ohms, p 〈 0.001) and a lower peak current (7.7±2.6 A vs. 10.1±3.7 A, p 〈 0.001) than the three-electrode system. Conclusions: A three-electrode defibrillation system that utilizes a dual coil transvenous lead and a subcutaneous pectoral electrode with lower capacitance is associated with a lower defibrillation energy requirement than is a dual coil defibrillation system with higher capacitance. This finding suggests that the utilization of a pectoral generator as a defibrillation electrode in conjunction with smaller capacitors is a more effective defibrillation system and may allow for additional miniaturization of implantable defibrillators.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1572-8595
    Keywords: Radiofrequency Energy ; PSVT ; Catheter Ablation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Temperature monitoring may be helpful for ablation of accessory pathways, however its role in ablation of atrioventricular nodal reentrant tachycardia (AVNRT) using the slow pathway approach is unclear. Therefore, the purpose of this study was to prospectively compare slow pathway ablation for AVNRT using fixed power or temperature monitoring. The study included 120 patients undergoing ablation for AVNRT. Patients were randomly assigned to receive either fixed power at 32 watts, or to temperature monitoring with a target temperature of 60°C. The primary success rate was 72% in the fixed power group and 95% in the temperature monitoring group (p=0.001). The ablation procedure duration (35±29 min vs 35±30 min; p=0.9), fluoroscopic time (32±17 vs 35±19 min; p=0.4), mean number of applications (10.2±8.1 vs 8.4±7.9; p=0.2), and coagulum formation per application (0.2% vs 0.5%; p=0.6) were statistically similar in the fixed power and temperature monitoring groups, respectively. The mean temperature (47.3±4.8°C vs 48.6±3.8°C; p〈0.01), and the temperature associated with junctional ectopy (48.2±3.8°C vs 49.3±3.6°C, p〈0.01) were less for the fixed power than the temperature monitoring group. In the temperature monitoring group, only 31% of applications achieved an electrode temperature of 60°C. During follow up of 6.6±3.6 months there were two recurrences in the fixed power group and one in the temperature monitoring group (p=1.0). In summary, power titration directed by temperature monitoring was associated with an improved primary procedural success rate. Applications of energy were associated with a temperature of approximately 50°C with both techniques, suggesting that there is a low efficiency of heating in the posterior septum.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Slow Pathway Ablation. Introduction: Successful radiofrequency ablation of an accessory pathway has been demonstrated to be associated with an electrode-tissue interface temperature of approximately 60°C or an impedance change of −5 to −10 Ω. However, the temperature and impedance changes associated with ablation of AV nodal reentrant tachycardia (AVNRT) using the slow pathway approach have not been reported. Therefore, the purpose of this study was to define the temperature and impedance changes achieved during ablation of AVNRT. Methods and Results: The study included 35 consecutive patients with AVNRT undergoing radiofrequency ablation of the slow pathway with a fixed power output of 32 W, and using a catheter with a thermistor bead embedded in the distal 4-mm electrode. The procedure was successful in each patient. The steady-state electrode-tissue interface temperature during successful applications of energy was 48.5 ± 3.3°C (range 42° to 56°C), and the steady-state temperature during ineffective applications was 46.8°± 5.5°C (P = 0.03). The mean impedance change during all applications of energy was −1.4 ± 2.8 ω, and did not differ significantly during effective and ineffective applications. Coagulum formation resulted during five applications (2.7%) in two patients (5.7%). There were no recurrences during 114 ± 21 days of follow-up. Conclusions: Successful ablation of AVNRT using fixed power output is achieved at an electrode-tissue interface temperature of approximately 48°C and is associated with a drop in impedance of 1 to 2 ω. These findings suggest that slow pathway ablation requires less heating at the electrode-tissue interface than does accessory pathway or AV junction ablation.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Defibrillation Energy Requirements. Introduction: Defibrillation energy requirements in patients with nonthoracotomy defibrillators may increase within several months after implantation. However, the stability of the defibrillation energy requirement beyond 1 year has not been reported. The purpose of this study was to characterize the defibrillation energy requirement during 2 years of clinical follow-up. Methods and Results: Thirty-one consecutive patients with a biphasic nonthoracotomy defibrillation system underwent defibrillation energy requirement testing using a step-down technique (20, 15, 12, 10, 8, 6, 5, 4, 3, 2, and 1 J) during defibrillator implantation, and then 24 hours, 2 months, 1 year, and 2 years after implantation. The mean defibrillation energy requirement during these evaluations was 10.9 ± 5.5 J, 12.3 ± 7.3 J, 11.7 ± 5.6 J, 10.2 ± 4.0 J, and 11.7 ± 7.4 J, respectively (P= 0.4). The defibrillation energy requirement was noted to have increased by 10 J or more after 2 years of follow-up in five patients. In one of these patients, the defibrillation energy requirement was no longer associated with an adequate safety margin, necessitating revision of the defibrillation system. There were no identifiable clinical characteristics that distinguished patients who did and did not develop a 10-J or more increase in the defibrillation energy requirement. Conclusion: The mean defibrillation energy requirement does not change significantly after 2 years of biphasic nonthoracotomy defibrillator system implantation. However, approximately 15% of patients develop a 10-J or greater elevation in the defibrillation energy requirement, and 3% may require a defibrillation system revision. Therefore, a yearly evaluation of the defibrillation energy requirement may he appropriate.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Cardiac Memory. Introduction: “Cardiac memory” (primary T wave change) is thought to occur after 15 minutes to several hours of right ventricular (RV) pacing. The two components of the temporal change in repolarization are memory and accumulation. The purpose of this study was to examine quantitatively the effect of short periods of ventricular pacing on the human cardiac action potential, using monophasic action potential (MAP) recordings. Methods and Results: Thirty-one patients (ages 43 ± 14 years) with structurally normal hearts undergoing a clinically indicated electrophysiologic procedure were enrolled. Catheters were placed in the right atrium (RA) and RV, and a MAP catheter was positioned at the RV septum. APD90 was calculated from digitized MAP recordings. MAP morphology comparisons were performed using the root mean square (RMS) of the difference between complexes. All pacing was at 500-msec cycle length. There were four pacing protocols: (1) RA pacing was performed for approximately 15 minutes to evaluate temporal stability of the MAP recordings (5 pts); (2) to evaluate the memory phenomenon, four successive 1-minute episodes of RV pacing were interspersed with 2 minutes of RA pacing (5 pts); (3) the accumulation phenomenon was evaluated by assessing the effects of 1, 5, 10, and 15 minutes of RV pacing on the MAP during RA pacing (16 pts); and (4) 20 minutes of RV pacing was followed by 10 minutes of RA pacing to correlate visually apparent T wave changes with changes in MAP recordings (5 pts). In the control patients, no changes in APD90 or RMS analysis were noted during 14.9 ± 1.4 minutes of RA pacing. In the second protocol, RMS of the difference between the baseline MAP complexes and the signal average of the first 50 beats following each of four 1-minute RV pacing trains demonstrated progressively greater differences in morphology after successive episodes of RV pacing. In protocol 3, RMS analysis identified a progressively greater difference between the baseline MAP recording and the average of the first 50 beats after 1,5, 10, and 15 minutes of RV pacing. In protocol 4, visually apparent changes in T waves occurred in parallel with the RMS of the difference between the baseline MAP recordings and the average of the first 50 beats after 20 minutes of RV pacing. Similar changes also were demonstrated by APD90 analysis. Conclusion: This study is the first to demonstrate that episodes of abnormal ventricular activation as short as 1 minute in duration may exert lingering effects on the repolarization process once normal ventricular activation resumes.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Fascicular Tachycardia. Introduction: Idiopathic left ventricular tachycardia typically has a right bundle branch block configuration. The purpose of this case report is to demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle also may have a left bundle branch block configuration. Methods and Results: A 27-year-old woman underwent an electrophysiologic procedure because of recurrent, verapamil-responsive, wide QRS complex tachycardia. Two types of ventricular tachycardia (cycle lengths 330 to 340 msec) were reproducibly inducible, one with a right bundle branch block configuration and left-axis deviation that had been documented clinically, and the other with a left bundle branch block configuration and axis of zero. A Purkinje potential recorded at the junction of the left ventricular mid-septum and inferior wall preceded the ventricular complex by 40 msec in both tachycardias. A single application of ra-diofrequency energy at this site successfully ablated both ventricular tachycardias. Conclusion: The findings of this case report demonstrate that idiopathic ventricular tachycardia arising in or near the left posterior fascicle may have a left bundle branch block configuration
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Ventricular Defibrillation and Cardiac Function. Introduction: The effect of implantable defibrillator shocks on cardiac hemodynamics is poorly understood. The purpose of this study was to test the hypothesis that ventricular defibrillator shocks adversely effect cardiac hemodynamics. Methods and Results: The cardiac index was determined by calculating the mitral valve inflow with transesophogeal Doppler during nonthoracotomy defibrillator implantation in 17 patients. The cardiac index was determined before, and immediately, 1 minute, 2 minutes, and 4 minutes after shocks were delivered during defibrillation energy requirement testing with 27- to 34-, 15-, 10-, 5-, 3-, or 1-J shocks. The cardiac Index was also measured at the same time points after 27- to 34-, and 1-J shocks delivered during the baseline rhythm. The cardiac index decreased from 2.30 ± 0.40 L/min per m2 before a 27- to 34-J shock during defibrillation energy requirement testing to 2.14 ± 0.45 L/min per m2 immediately afterwards (P= 0.001). This effect persisted for 〉4 minutes. An adverse hemodynamic effect of similar magnitude occurred after 15 J (P= 0.003) and 10-J shocks (P= 0.01), but dissipated after 4 minutes and within 2 minutes, respectively. There was a significant correlation between shock strength and the percent change in cardiac index (r = 0.3, P= 0.03). The cardiac index decreased 14% after a 27- to 34-J shock during the baseline rhythm (P 〈 0.0001). This effect persisted for 〈4 minutes. A 1- J shock during the baseline rhythm did not effect the cardiac index. Conclusion: Defibrillator shocks 〉9 J delivered during the baseline rhythm or during defibrillation energy requirement testing result in a 10% to 15% reduction in cardiac index, whereas smaller energy shocks do not affect cardiac hemodynamics. The duration and extent of the adverse effect are proportional to the shock strength. Shock strength, and not ventricular fibrillation, appears to be most responsible for This effect. Therefore, the detrimental hemodynamic effects of high-energy shocks may be avoided when low-energy defibrillation is used.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Low-Energy Defibrillation. Introduction: In patients undergoing defibrillator implantation, an appropriate defibrillation safety margin has been considered to be either 10 J or an energy equal to the defibrillation energy requirement. However, a previous clinical report suggested that a larger safety margin may be required in patients with a low defibrillation energy requirement. Therefore, the purpose of this prospective study was to compare the defibrillation efficacy of the two safety margin techniques in patients with a low defibrillation energy requirement. Methods and Results: Sixty patients who underwent implantation of a defibrillator and who had a low defibrillation energy requirement (≤ 6 J) underwent six separate inductions of ventricular fibrillation, at least 5 minutes apart. For each of the first three inductions of ventricular fibrillation, the first two shocks were equal to either the defibrillation energy requirement plus 10 J (14.6 ± 1.0 J), or to twice the defibrillation energy requirement (9.9 ± 2.3 J). The alternate technique was used for the subsequent three inductions of ventricular fibrillation. For each induction of ventricular fibrillation, the first shock success rate was 99.5%± 4.3% for shocks using the defibrillation energy requirement plus 10 J, compared to 95.0%± 17.2% for shocks at twice the defibrillation energy requirement (P = 0.02). The charge time (P 〈 0.0001) and the total duration of ventricular fibrillation (P 〈 0.0001) were each approximately 1 second longer with the defibrillation energy requirement plus 10 J technique. Conclusion: This study is the first to compare prospectively the defibrillation efficacy of two defibrillation safety margins. In patients with a defibrillation energy requirement ≤ 6 J, a higher rate of successful defibrillation is achieved with a safety margin of 10 J than with a safety margin equal to the defibrillation energy requirement.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Unipolar Electrogram. Introduction: The purpose of this study was to determine the accuracy of the unipolar electrogram for identifying the earliest site of ventricular activation. The earliest site of ventricular activation may be identified with the unipolar electrogram by the absence of an R wave. However, the accuracy of this technique is unknown. Methods and Results: A single ventricular premature complex was induced mechanically at the tip of an electrode catheter to simulate a ventricular premature depolarization site of origin. Unipolar electrograms were recorded from the right ventricular septum at the tip electrode and at 2, 5, 8, and 11 mm from the electrode tip in 20 patients. No R waves were detected at the ventricular premature depolarization site of origin. R waves were detected in 4 of 20 patients (20%) at 2 mm from the tip electrode and 7 of 20 patients (35%) at 5, 8, and 11 mm from the tip electrode. An R wave was not observed at distances ≤ 11 mm from the site of tachycardia origin in 13 of 20 patients (65%). Conclusions: While an R wave in the unipolar electrogram can he seen as close as 2 mm from the site of impulse origin, the absence of an R wave as an indicator of the site of impulse origin in the right ventricle is highly inaccurate. Therefore, the absence of an R wave in the unipolar electrogram is unlikely to be an adequate guide for identification of an effective target site for ablation of right ventricular tachycardia.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Tedisamil Conversion of AF in Two Canine Models. Introduction: Tedisamil is an experimental bradycardic agent possessing action potential-prolonging effects. It has been proven effective in terminating ventricular arrhythmias in several animal models and atrial flutter in a conscious dog model. There are no reports to date evaluating tedisamil's efficacy in terminating atrial fibrillation (AF). Methods and Results: Two different canine models of AF were used. One group of dogs (n = 6) was subjected to 28 days of chronic fibrillatory pacing at 50 Hz using an implantable neural stimulator. Sustained AF was achieved in all dogs within 14 days of initiating pacing. A second set of dogs (n = 5) had AF induced via bilateral vagal stimulation. Tedisamil 1 mg/kg was 100% effective in terminating AF in both models. Cardioversion was associated with a statistically significant prolongation of the fibrillatory cycle length immediately before return to normal sinus rhythm in both models. A dose-response trial was performed in the vagal AF group as well as in a second group of three dogs that underwent chronic fibrillatory pacing. The efficacy of tedisamil was dose dependent, with limited efficacy at 0.1 and 0.3 mg/kg intravenously in both models. Tedisamil was able to prevent reinduction of sustained AF 30 minutes after administration of 1 mg/kg in the chronic pacing model in all dogs. Side effects included minor hypersalivation in most dogs receiving the 1 mg/kg dose. No ventricular ectopy or arrhythmias were observed. Conclusion: Tedisamil is effective for conversion of sustained AF to normal sinus rhythm in two different models of AF.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...