Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    facet.materialart.
    Unknown
    German Medical Science; Düsseldorf, Köln
    In:  67. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie, 89. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie und 44. Tagung des Berufsverbandes der Fachärzte für Orthopädie; 20031111-20031116; Berlin; DOC03dguF3-12 /20031111/
    Publication Date: 2003-11-11
    Keywords: ddc: 610
    Language: German
    Type: conferenceObject
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    facet.materialart.
    Unknown
    German Medical Science GMS Publishing House; Düsseldorf
    In:  Deutscher Kongress für Orthopädie und Unfallchirurgie (DKOU 2013); 20131022-20131025; Berlin; DOCWI60-265 /20131023/
    Publication Date: 2013-10-24
    Keywords: MPFL-Rekonstruktion ; Biomechanik ; Quadricepssehne ; ddc: 610
    Language: German
    Type: conferenceObject
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    German Medical Science GMS Publishing House; Düsseldorf
    In:  Deutscher Kongress für Orthopädie und Unfallchirurgie (DKOU 2015); 20151020-20151023; Berlin; DOCPO12-1541 /20151005/
    Publication Date: 2015-10-06
    Keywords: Bandrekonstruktionen ; flache Transplantate ; Biomechanik ; ddc: 610
    Language: German
    Type: conferenceObject
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    facet.materialart.
    Unknown
    German Medical Science; Düsseldorf, Köln
    In:  68. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie, 90. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie und 45. Tagung des Berufsverbandes der Fachärzte für Orthopädie; 20041019-20041023; Berlin; DOC04dguJ5-115 /20041019/
    Publication Date: 2004-10-20
    Keywords: ddc: 610
    Language: German
    Type: conferenceObject
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Vordere Kreuzbandplastik ; Interferenzschraube ; Bioresorbierbares Implantat ; Keywords Anterior cruciate ligament reconstruction ; Interference screw ; Bioabsorbable implants
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary To overcome some of the potential problems (e.g. hardware removal during revision surgery) of metall interference screws used for patellar tendon anterior cruciate ligament reconstruction, bioabsorbable screws have recently been introduced. Forty patients who underwent endoscopic ACL reconstruction using patella tendon autograft were included in the study, they were randomized intraoperatively to either Group A (femoral bone block fixation: polyglyconate screw; tibial: metall screw) or Group B (both bone blocks fixed with metall interference screws). The patients were evaluated clinically preoperatively as well as 6 weeks, 3 months 12 months and 24 months post op. Lysholm Score at 24 months was 98,1±2,3 for Group A and 97,7±3,0 for Group B. Tegner Score was 7,4±1,1 for Group A and 7,5±0,8 for Group B. Two years post op overall IKDC-Score for group A was 5,6% normal, 88,8% nearly normal and 5,6% abnormal. The result for group B was 11,1%, 77,8% and 11,1%, respectively. KT-1000 (at 89 N) at two years revealed a side to side difference of 1,5±0,3 mm (Group A) and 1,6±0,7 (Group B). The results of the two groups did not show significant differences at any stage of follow up. In our study polyglyconate interference screw fixation for patellar tendon grafts has not found to be associated with increased clinical complications. It provided equivalent fixation and clinical results compared to metall screws.
    Notes: Zusammenfassung Durch die Verwendung von resorbierbaren Interferenzschrauben zur Transplantatfixation bei vorderer Kreuzbandrekonstruktion sollen potentielle Nachteile von Metallschrauben vermieden werden. In einer prospektiv randomisierten Studie wurde bei 20 Personen (Gruppe A) der femorale Knochenblock eines Lig.-patellae-Knochen-Sehnen-Knochentransplantats mit einer resorbierbaren Polyglykonatschraube befestigt, bei 20 Personen der Kontrollgruppe (Gruppe B) mit einer Metallinterferenzschraube. Über einen Zeitraum von 2 Jahren wurden die Patienten klinisch und radiologisch nachuntersucht. Sowohl Tegner- (im Mittel 7,4±1,1 für Gruppe A bzw. 7,5±0,8 für Gruppe B bei Studienende) als auch Lysholm- (im Durchschnitt 98,1±2,3 für Gruppe A, 97,7±3,0 Gruppe B) und IKDC-Score (5,6% normal, 88,8% fast normal, 5,6% abnormal in Gruppe A bzw. 11,1% 77,8% und 11,1% in Gruppe B) zeigten einen ähnlichen Verlauf den gesamten Zeitraum über, es bestand zu keinem Zeitpunkt der Untersuchung ein signifikanter Unterschied zwischen beiden Gruppen. Anhand der Röntgenbilder konnte die Polyglykonatschraube bis 6 Wochen postoperativ identifiziert werden und war dann nicht mehr erkennbar. Abnorme radiologische Veränderungen (Osteolysen etc.) traten in beiden Gruppen nicht auf. Bei mit bioresorbierbaren Schrauben behandelten Patienten kam es zu keinen entzündlichen Abwehrreaktionen. Polyglykonatinterferenzschrauben eignen sich in gleicher Weise wie Metallimplantate zur Fixierung des autologen Lig.-patellae-Transplantats bei der vorderen Kreuzbandplastik.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1433-0385
    Keywords: Keywords: Per- and subtrochanteric fracture – Gamma nail – Mobility – Complication. ; Schlüsselwörter: Per- und subtrochantäre Fraktur – Gammanagel – Mobilisation – Komplikation.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung. Einleitung: Ziel dieser retrospektiven Studie ist es, den Einfluß von Alter, Begleiterkrankungen, Frakturform, Operationszeitpunkt, Wahl des Implantats (kurzer oder langer Gammanagel) und Operationsverfahren auf Mobilisationsgrad, radiologischen Heilungsverlauf und mögliche Komplikationen nach operativer Stabilisierung von per- und subtrochantären Oberschenkelbrüchen mittels Gammanagel zu analysieren. Patienten und Methoden: Von 1992 bis 1997 wurden 96 Patienten mit isolierter per- oder subtrochantärer Oberschenkelfraktur mittels Gammanagel (Howmedica) operiert. Das Durchschnittsalter der Patienten zum Zeitpunkt der Verletzung betrug 72,5 (27–101) Jahre. 27 Patienten waren Männer, und 69 waren Frauen. Die Operation erfolgte durchschnittlich 1,19 (0–10) Tage nach dem Unfall. Die postoperativen Kontrollen erfolgten nach 3, 6 und 12 Monaten. Hierbei wurden jeweils Röntgenaufnahmen des Oberschenkels mit Hüftgelenk in 2 Ebenen durchgeführt und der Mobilisationsgrad der Patienten beurteilt. Ergebnisse: Begleiterkrankungen, Operationszeitpunkt, Frakturtyp, Operationsverfahren und Wahl des Implantats (kurzer oder langer Gammanagel) hatten keinen Einfluß auf den Grad der Mobilisation, auf den radiologischen Heilungsverlauf oder auf aufgetretene Komplikationen. Ältere Patienten ( 〉 70 Jahre) waren schlechter mobilisierbar (p 〈 0,001). Ein Jahr nach dem Unfall waren 97 % der Frakturen radiologisch geheilt. Bei 15 Patienten (18 %) kam es zu technischen Komplikationen bei der Verwendung des Gammanagels. Schlußfolgerungen: Per- und subtrochantäre Oberschenkelfrakturen können mit Hilfe des Gammanagels bei richtiger Handhabung stabil versorgt und die Patienten frühzeitig mobilisiert werden.
    Notes: Abstract. Background: From 1992 through 1997 96 patients with per- or subtrochanteric femur fractures were treated with a Gamma nail. We retrospectively evaluated the influence of patient age, additional diseases, type of fracture, time of operation, type of implant (short/long Gamma nail) and surgical approach (open/closed reduction) on the mobility of the patients, healing of the fractures on radiographs, and possible complications. Patients and methods: The average patient age was 72.5 years (range 27 to 101). There were 27 male and 69 female patients. Surgery was performed 1.19 (0–10) days after injury. At 3, 6, and 12 months after surgery radiographs of the involved hip joint and femur were obtained and the degree of mobility was assessed. Results: Additional diseases, type of fracture, time of operation, type of implant (short/long Gamma nail) and surgical approach (open/closed reduction) did not influence mobility of the patients, healing of the fractures on radiographs or rate of complications. It was more difficult to mobilize older patients (P 〈 0.001). After 1 year 97 % of all fractures had healed on radiographs. In 15 patients (18 %) complications occurred due to technical errors using the Gamma nail. Discussion: With the Gamma nail stable osteosynthesis of per- and subtrochanteric femur fractures is obtained independently of the fracture classification. Patients can be mobilized immediately. Technical errors must be avoided.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Ambulante Thromboseprophylaxe ; Immobilisierende Stützverbände ; Verletzungen an der unteren Extremität ; Keywords Thrombosis prophylaxis ; Outpatients ; Immobilizing bandages ; Lower limb injuries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Selected patients with minor lower limb injuries and low risk for deep vein thrombosis (DVT), who required cast immobilizing and did not receive medical thrombosis prophylaxis, were included in a prospective study. The decision to give not medical thrombosis prophylaxis depended on an concept of individualised prophylaxis for patients at risk for thromboembolism. From March 1994 to March 1996 in 178 outpatients (118 men, 60 women, mean age 25,8 [16–39] years) a clinical examination and a colour-coded duplex sonography were performed after removel of the cast for detection of DVT of the lower limb. A phlebographie was performed when thrombosis was suspected. Two patients developed a one bundle thrombosis of the calf. Clinical appearance of lung embolism was not observed. These results suggest, that low risk patients with minor injuries of the lower limb and plaster cast immobilisation do not need a medical thrombosis prophylaxis.
    Notes: Zusammenfassung In einer Beobachtungsstudie wurden 178 ambulante Patienten mit Verletzungen an der unteren Extremität, die nach Abwägung ihres individuellen Thromboserisikos anhand einer Checkliste keine medikamentöse Thromboembolieprophylaxe erhielten; auf das Auftreten von tiefen Beinvenenthrombosen getestet. Nach Abnahme des Gipsverbands nach durchschnittlich 14,4 (Range 5–48) Tagen erfolgte eine klinische und farbkodierte duplexsonographische Untersuchung. Bei positiven Ausfall einer oder beider Untersuchungen wurde eine Phlebographie durchgeführt. Von den 178 untersuchten Studienpatienten entwickelten 2 Patienten eine isolierte Einbündelunterschenkelvenenthrombose (Thromboseinzidenz 1,1%, 95-%-Konfidenzintervall 0–4,4%). Eine Lungenembolie wurde bei keinem Patienten beobachtet. Aufgrund unserer Ergebnisse erscheint eine generelle medikamentöse Thromboembolieprophylaxe bei jungen, gesunden Patienten mit einer Verletzung an der unteren Extremität und einer Ruhigstellung im Gipsverband nicht indiziert.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1433-044X
    Keywords: Key words Acute compartment syndrome • Exertion ; Schlüsselwörter Akutes Kompartmentsyndrom •Überbelastung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Akute Kompartmentsyndrome der unteren Extremität treten in der unfallchirurgischen Praxis vor allem posttraumatisch – nach Frakturen oder direkten Traumen – sowie postischämisch auf. Als Folge einer übermäßigen Belastung, wie etwa langen Märschen, wird das Krankheitsbild vorwiegend in der militärmedizinischen Literatur beschrieben. Als nicht traumatische Ursachen sind zu erwähnen die akute Rhabdomyolyse, medikamenteninduzierte Myositis und eosinophile Myositis. Wir berichten über den klinischen und MR-tomographischen Verlauf eines Kompartmentsyndroms, aufgetreten in Folge einer Distorsion des oberen Sprunggelenks (OSG).
    Notes: Summary In the field of traumatology, compartment syndromes of the lower extremity are often seen after fractures and direct injuries, or after ischaemia. Other causes include over-exertion and non-traumatic causes such as acute rhabdomyolysis, drug-induced myositis and eosinophilic myositis. This paper describes the clinical and MR course of a compartment syndrome following an ankle sprain.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1433-044X
    Keywords: Schlüsselwörter Vordere Kreuzbandruptur ; Konservative Therapie ; Operative Therapie ; Key words Anterior cruciate ligament reconstruction ; Conservative treatment ; Surgery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: The treatment of anterior cruciate ligament (ACL) rupture continues to be a controversial subject. This study was undertaken to compare long-term results of different therapy regimens A total of 52 patients (mean age: 34.7±3.2 years) who underwent ACL reconstruction using the central one third of the patellar tendon and 32 patients (mean age: 38.3±5.2 years) treated conservatively were evaluated 5–7 years clinically, radiologically and with respect to their sports activities. In all, 25% of the patients operated on subjectively rated their knees as ``excellent'', 40.4% as ``very good'', 22.2% ``good'', 12.5% ``fair'' and 0% as ``poor''. The ratings for the conservatively treated group were: 12.9%, 19.4%, 29%, 25.8% and 12.5%, respectively. The results of the OAK score were significantly better for the surgically treated group (87.5±7.1 points compared with 77.1±13.4). An increasing number of degenerative changes were found on radiographs in both groups at follow-up as compared with their pre-injury status.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1433-7347
    Keywords: Keywords Knee arthrometry ; Electromyographic biofeedback ; Anterior cruciate ligament
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Sports Science
    Notes: Abstract Two studies were undertaken to evaluate the use of EMG biofeedback to encourage hamstring relaxation during KT-1000 measurement of anterior tibial displacement. In study 1, 60 ACL-deficient patients were studied in three groups using 15 lb and 20 lb in each group: in group 1 the patients were simply retested 15 min after the initial test sequence, in group 2 they were initially retested with EMG biofeedback and then again without, and in group 3 they were retested twice with EMG biofeedback. No significant difference in mean anterior tibial displacement was seen between the initial measurements and retest measurements when no EMG biofeedback was used. A significant ¶increase in mean anterior tibial displacement was seen when the retesting was performed with EMG biofeedback. No further increase was seen with repeated retesting with EMG biofeedback. In study 2, 40 patients were evaluated 4–12 months following ACL reconstruction. KT-1000 measurements of anterior tibial displacement of both the operated and non-operated knees were made at 15 lb and 30 lb with and without the use of EMG biofeedback. EMG biofeedback was associated with a significant increase in unilateral measurement of anterior tibial displacement. When side-to-side differences were compared, there was a small but statistically significant increase in anterior tibial displacement with the use of EMG biofeedback. Although the use of EMG biofeedback to encourage hamstring relaxation does increase unilateral measurements of anterior tibial displacement, it does not appear to have a clinically significant effect on measurement of side-to-side difference. It may have a role in testing patients who have difficulty achieving hamstring relaxation or in aiding inexperienced examiners.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...