Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Keywords
Language
Years
  • 1
    facet.materialart.
    facet.materialart.
    German Medical Science GMS Publishing House; Düsseldorf
    In:  124. Kongress der Deutschen Gesellschaft für Chirurgie; 20070501-20070504; München; DOC07dgch6655 /20071001/
    Publication Date: 2007-10-02
    Keywords: ddc: 610
    Language: German
    Type: conferenceObject
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 15 Schafen implantierten wir in jede Tibiadiaphyse 3 Corticaliszugschrauben. Der postoperativ zwischen Schraube und Senklochsowie Gleitlochanteil der Corticalis bestehende Spalt veränderte sich während 112 Tagen Beobachtungszeit wie folgt: Bis zum 7. Tage war dieser mit fibrösem Knochen und anschließend wurde er mit lamellärem Knochen aufgefüllt. Das im ehemaligen Gleitloch nach 112 Versuchstagen befindliche lamelläre Knochengewebe hielt ca. 41% Ausrißbelastbarkeit gegenüber einer normalen Corticalis stand. Nach vollständiger Auffüllung des Spaltes scheinen sich die primär mit der Zugschraube aufgebrachten Zugkräfte auf größere Flächen zu verteilen.
    Notes: Summary Leg screws were implanted in 30 tibia diaphysis. 112 days later in the gliding hole there was new lamellar bone round of the screw head, neck of screw and into the both first screw threads. After screw explantation we measured in 8 cases the solidity of the new bone. Under conditions of tension measurement, we use 341 N per millimeter cortical thread surfaces to put out all new bone from the gliding hole. The results of these tension measurements were cylindric fragments. The remodelling into the gliding hole seems to be the results of static stress and dynamic compensation for reaching a defect in living cortical bone.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Zum besseren Verständnis der Frakturfixation ausgelöst durch interfragmentären Druck haben wir das Anzug- und Lösemoment an Osteosyntheseschrauben (AO) bestimmt. Die Messungen fanden an der Tibia und Femur des Schafes statt. Geprüft wurden die 3,5- und 4,5 mm-AO-Corticalisschrauben in vitro und in vivo. Die Verweildauer der Implantate betrug 2–4 sec. Je nach Applikation bestand ein signifikanter Unterschied, in dem der Abfall des Lösemomentes über dem Anzugsmoment bei der Zugschraube 16,6% und bei der Stellschraube 55% betrug. Diese Unterschiede dürften auf der unterschiedlichen Deformation des Knochens beruhen.
    Notes: Summary For the better understanding of fracture fixation by means of screws the torque at application and at removal has been measured. The experiment were performed on sheep tibiae and femora in vitro and in vivo, whereby the 3.5 or 4.5 mm cortical bone-screws (AISF) were removed after 2–4 sec. There was a significant difference between the two values of torque in both types of screws, especially the torque at removal beeing 16.6% less for the lag screw and 55% less for a screw with two threaded holes (p〈0.01). The explication of these difference taking into consideration the deformation of bone in transverse axis.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-3916
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung An 17 Schafen wurden in beide Tibiadiaphysen 4,5 mm AO-Corticalisschrauben mit glatter und rauher Oberfläche nach dem Zugschraubenprinzip mit einem konstanten Anzugsmoment von 68,6 Ncm implantiert und am 0., 7., 28., 56. und 112. Tage die Lösemomente bestimmt. Die Lösemomente der Schrauben mit glatter Oberfläche fielen kontinuierlich bis zum 28. Tage ab und blieben dann etwa konstant. Bei Schrauben mit rauher Oberfläche stieg das Lösemoment nach dem 7. Tage stetig an und erreichte am 112. Tage den ca. 8fachen Betrag des Lösemomentes gegenüber jenen bei Versuchsbeginn. Aus den zeit- und schraubenoberflächenabhängigen Lösemomenten muß geschlossen werden, daß bei Zugschrauben mit rauher Oberfläche ab 28. Implantationstage eine festere Schrauben-Knochen-Verbindung vorlag.
    Notes: Summary The experiment was performed on 17 sheep tibiae in vivo. 4.5 mm ASIF leg screws with a constant insertion torque (68.6 Ncm) but different surfaces (smooth or rough) were removed after 3 s, 7, 28, 56 and 112 days after insertion. The screws with a rough surface which were implanted for 28 days and longer exhibited a significantly greater removal torque. For instance rough screws which were implanted for 112 days displayed a removal torque eight times greater than after 3 s.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...