Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 28 (1989), S. 34-38 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Methylisothiazolones ; Preservatives ; Analysis of cosmetics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Antimicrobially active formulations based on 2-methyl-3(2H)-isothiazolone and 5-chloro-2-methyl-3(2H)-isothiazolone (Kathon CG, Euxyl K 100) are incorporated into manufactured cosmetics as preservatives. In this paper we report on the analysis of these active components by means of liquid chromatography. It is conventional for the original methylisothiazolone components in cosmetics to be analyzed by reversed phase high-performance liquid chromatography after column chromatographic separation and flash chromatographic purification. In our new analytical method the methylisothiazolones are converted into the respective β-thiosubstituted acrylamide derivatives, which are ionic substances, with the help of the nucleophilic reagent hydrogensulfite. An ion pair high-performance liquid chromatographic method has been developed for the separation and quantification of these derivatives.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Methoden zum Nachweis und zur Identifizierung der in Methyl- bzw. Octylisothiazolon-Formulierungen (Kathon CG bzw. Kathon 893) enthaltenen Isothiazolonderivate mittels Hochleistungs-Flüssig-Chromatographie werden angegeben. Zur Trennung von 2-Methylisothiazol-3-on, 5-Chlor-2-methyl-isothiazol-3-on und 4,5-Dichlor-2-methyl-isothiazol-3-on sowie 2-n-Octyl-isothiazol-3-on sind verschiedene Umkehr-Phasen-Systeme geeignet. Mit Hilfe eines Dioden-Array-Detektors wurden die UV-Spektren der Isothiazolone nach HPLC-Trennung On-Line ausgemessen und die Absorptionsmaxima ermittelt. Der Einsatz eines Dioden-Array-Detektor-Systems bietet durch die Aufnahme von Isogrammen darüber hinaus Möglichkeiten zur Kontrolle der Peakreinheit sowie zur positiven Peakidentifizierung insbesondere in Proben mit komplexer Matrix.
    Notes: Summary High-performance liquid chromatographic methods are described for the detection and identification of isothiazolone derivates in methyl and octyl isothiazolone formulations (Kathon CG resp. Kathon 893). For the separation of 2-methyl-isothiazol-3-one, 5-chloro-2-methyl-isothiazol-3-one, 4,5-dichloro-2-methyl-isothiazol-3-one and 2-n-octyl-isothiazol-3-one different reversed-phase HPLC systems are suitable. Ultraviolet spectra and absorption maxima of isothiazolones were measured by using an on-line diode array detector. Control of peak purity as well as positive peak identification could be achieved by surveying isogrammes especially in samples with complex matrix.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Isolierung von 2-Methyl-isothiazol-3-on und 5-Chlor-2-methyl-isothiazol-3-on bzw. 2-n-Octylisothiazol-3-on aus den entsprechenden handelsüblichen Formulierungen wie Kathon CG bzw. Kathon 893 wird eine einfache, rasch durchzuführende Methode beschrieben. Die Methode basiert auf Fraktionierung durch Anwendung der Flash-Chromatographie — einer optimierten Variante der Niederdruck-Säulen-Chromatographie. Die erhaltenen Fraktionen wurden mit Hilfe von Dünnschicht-Chromatographie und Hochleistungs-Flüssigkeits-Chromatographie auf ihre Identität und Reinheit untersucht. Anschließend wurden die Gehalte mit einer im Halbmikromaßstab ausgeführten maßanalytischen Absolutmethode bestimmt. Diese Lösungen können als Eichbzw. Kalibrierungsstandards für Quantifizierungszwecke verwendet werden.
    Notes: Summary A method is described for the separation of 2-methyl-isothiazol-3-one and 5-chloro-2-methyl-isothiazol-3-one resp. 2-n-octyl-isothiazol-3-one from corresponding commercial formulations as Kathon CG resp. Kathon 893. This simple and fast method is based on fractionation by flash chromatography — an optimized version of low-pressure column chromatography. The fractions received were analyzed by thin-layer chromatography and high-performance liquid chromatography regarding their identity and purity. The isothiazolone contents were determined by an iodometric absolute method. These solutions can be used as calibration standards for quantification.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Methyl resp. octyl isothiazolone formulations (Kathon CG resp. Kathon 893) were fractionated by flash chromatography to receive their microbiocidal major components which were investigated by ultraviolet spectrophotometry. UV-spectra and absorption spectral data of 2-methyl-isothiazole-3-one, 5-chloro-2-methyl-isothiazole-3-one, 4,5-dichloro-2-methyl-isothiazole-3-one and 2-noctyl-isothiazole-3-one are given. The isothiazolones considered have their main absorption maxima between 275 and 281 nm. The logarithmic molar extinction coefficients differ from 3.82 to 3.92 for a defined wavelength of 280 nm. Selected compounds, as 6-methoxy-2-methylbenzothiazole and 2-acetyl-5-chlorothiophene were also analysed by ultraviolet spectrophotometry to be used as an internal standard for quantitative high-performance liquid-chromatographic analysis with UV-detection (280 nm). 2-Acetyl-5-chlorothiophene (3.79) is more suitable than 6-methyl-2-methylbenzothiazole (3.99), because of a more favourable logarithmic molar extinction coefficient at 280 nm.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary For quantification of 2-methyl-3(2H)-isothiazolone and 5-chloro-2-methyl-3(2H)-isothiazolone resp. 2-n-octyl-3(2H)-isothiazolone by means of chromatography it was necessary to obtain the purified 3(2H)-isothiazolones as reference substances. Therefore the corresponding commercial isothiazolone formulations as Kathon CG resp. Kathon 893 were fractionated by reversed flash chromatography and the exact contents were determined by an iodometric absolute method. These solutions were used as calibration standards for quantification. For the quantitative determination of the above mentioned 3(2H)-isothiazolones reversed phase HPLC has proved to possess good reliability using the internal standard method with 2-acetyl-5-chlorothiophene. Response factors and the relative calibration curves for this method were ascertained.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Keywords: Best. von Tensiden in Shampoo, Schaumbäder ; Chromatographie, Dünnschicht ; Alkylsulfate, Alkylethersulfate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Ein dünnschicht-chromatographisches Verfahren wird beschrieben, mit dem eine einfache und schnelle Identifizierung von Tensiden möglich ist. Das Verfahren eignet sich besonders zum Nachweis von Alkylsulfaten und Alkylethersulfaten. Diese Tenside finden vielfach als Basiskomponenten in Shampoos und Schaumbadepräparaten Verwendung. Zur Detektion können verschiedene Reagentien herangezogen werden, deren Farbreaktionen geprüft und zusammengestellt wurden. Besonders geeignet und empfindlich ist die Detektion mit Pinakryptolgelb-Reagens. Für diese Nachweisreaktion wurden die Nachweisgrenzen ermittelt.
    Notes: Summary A thin-layer chromatographic procedure is described for a simple and rapid identification of surfactants. It is especially suitable for the identification of alkyl sulphates and alkyl ether sulphates. These surfactants are often used as basic components of shampoos and foam bath preparations. For detection, various indicators can be used; their colour reactions were examined and listed. Especially adequate and sensitive for detection is the pinacryptol yellow reagent. The detection limits for this identifying reaction were ascertained.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Keywords: Isolierung von Antimikrobiellen Stoffen aus Kosmetika, Shampoos, Schaumbadepräparaten, Seifen ; Chromatographie, Säulen ; tensidhaltige Substanzen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Best. von Phenolen, Antimikrobiellen Stoffen in Cosmetica, Shampoos, Badepräparaten ; Chromatographie, Säulen, Gas, HPLC ; tensidhaltig, Silylierung, Methylierung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird ein säulen-chromatographisches Verfahren zur einfachen und raschen Isolierung phenolischer antimikrobieller Substanzen aus nicht-emulsionsartigen Substraten beschrieben. Die Bestimmung wurde an Modellsubstraten mit 11 bzw. 14 zugesetzten phenolischen Substanzen mittels GC und HPLC durchgeführt. Mit Hilfe der HPLC konnten 11 dieser Verbindungen bei einer Detektionswellenlänge von 290 nm simultan direkt erfaßt werden. Dagegen wurden bei 260nm nur pHB-Methylester und pHB-Propylester detektiert, die bei 290nm nicht registriert wurden. Zur gas-chromatographischen Erfassung hat sich die Derivatisierung zu Methyl- bzw. Trimethylsilyl-Ethern als geeignet erwiesen. Die Vorund Nachteile der Derivatisierungsmethoden werden diskutiert. Für die TMS-Ether von 11 phenolischen antimikrobiellen Substanzen im Gemisch wurden die Wiederfindungsraten bei Gehalten von je ca. 0,2%, nach Isolierung aus Shampoos und Schaumbadpräparaten bestimmt.
    Notes: Summary A column-chromatographic procedure for a simple and rapid separation of phenolic antimicrobials from non-emulsified cosmetics containing surfactants is described. By means of GLC and HPLC the determination was performed in model substrates containing 11, and in some cases 3 additional phenolic substances. With the aid of HPLC, 11 of these compounds could be recorded simultaneously and directly at a wavelength of 290 nm. Only pHB ethyl ester and pHB propyl ester which had not been recorded at 290 nm were detected at 260nm. For gas-chromatographic recording the derivatization into methyl and trimethylsilyl ethers has proved to be suitable. The advantages and disadvantages of the derivation methods are discussed. The recovery rates (for approximate contents of 0.2% each) for the TMS ethers of 11 phenolic antimicrobials in composition were ascertained after separation from shampoos and foam bath preparations.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Zur Bestimmung von 5-Brom-5-nitro-1,3-dioxan in tensidhaltigen nicht-emulsionsartigen Cosmetica wie Shampoos, Schaum- und Duschbädern wurde — unter Berücksichtigung eines zu erwartenden Konzentrationsbereichs von 0,001–0,1% sowie der allgemein bekannten Problematik der Abtrennung von Wirkstoffen aus Tensidmatrices 3- eine schnelle und einfach durchzuführende, für die Routine geeignete Analysenmethode entwickelt. Die qualitative und quantitative Bestimmung erfolgt gas-chromatographisch mittels Electron-Capture Detector (ECD) nach säulen-chromatographischer Isolierung. Aufgrund der hohen Elektronenaffinität des Moleküls und der daraus resultierenden Selektivität des ECD's wird 5-Brom-5-nitro-1,3-dioxan äußerst empfindlich registriert, so daß die Nachweisgrenze 2 pg absolut beträgt. Die durchschnittlichen Wiederfindungsraten wurden im angegebenen Konzentrationsbereich zu 96% ermittelt. Die Standardabweichung beträgt ±0,14 mg/100 g bei einem mittleren Gehalt von 2 mg/100 g. Der Zeitaufwand für parallel durchgeführte Doppelanalysen beträgt etwa 60 min. An einer Auswahl von Handelsproben wurde die Methode geprüft. Danach enthielten von 18 untersuchten Proben acht 5-Brom-5-nitro-1,3-dioxan zwischen 0,002 und 0,04%.
    Notes: Summary A simple and rapid method suitable for routine analysis was developed to determine 5-bromo-5-nitro-1,3-dioxane in non-emulsified cosmetics containing surfactants. Its concentration in shampoos, foam baths and shower bath preparations was expected between 0.001 and 0.1%. The qualitative and quantitative determination was made by gas chromatography with an electron-capture detector (ECD) after column-chromatographic separation. The sensitive recording of 5-bromo-5-nitro-1,3-dioxane is due to the intensive electron affinity of the molecule and the selectivity of the ECD. The detection limit is 2 pg. The average recovery rate in the given concentration range was ascertained to be 96%. The standard deviation is ±0.14mg/100g for an average content of 2mg/100g. The expenditure of time for a duplicate determination is about 60 min. A selection of 18 commercial products was examined. Eight samples contained 0.002–0.04% of 5-bromo-5-nitro-1,3-dioxane.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Methylisothiazolon-PrÄparate wurden nach Extraktion und dünnschicht-chromatographischer Fraktionierung mittels Capillar-Gas-Chromatographie/ Massenspektrometrie untersucht. 2-Methyl-isothiazol-3-on and 5-Chlor-2-methyl-isothiazol-3-on wurden als Hauptbestandteile sowie 4,5-Dichlor-2-methyl-isothiazol-3-on, 3-Chlor-N-methyl-propionamid und Dichlor-N-methyl-acetamid als Nebenbestandteile identifiziert. In dem untersuchten Octylisothiazolon-PrÄparat wurde als Wirkstoff 2-n-Octyl-isothiazol-3-on identifiziert; chlorierte Verbindungen konnten nicht nachgewiesen werden.
    Notes: Summary Methyl-isothiazolone products were investigated with capillary gas chromatography/mass Spectrometry after extraction and thin-layer chromatographic separation. 2-methyl-isothiazol-3-one and 5-chloro-2-methyl-isothiazol-3-one were identified as major components and 4,5-dichloro-2-methyl-isothiazol-3-one, 3-chloro-N-methylpropionamide and dichloro-N-methyl-acetamide as minor components. 2-n-octyl-isothiazol-3-one was identified as the active agent in an octyl isothiazolone product whereas chlorinated compounds could not be found.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...