Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Intracerebral malignant fibrous histiocytoma (MFH) ; CT ; MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The CT and MRI findings in a case of an intracranial malignant fibrous histiocytoma are reported. Pathological correlation was demonstrated and tumour vascularization was best seen at angiography. Despite its low incidence in brain. MFH is of special interest because of its ubiquitous location and poor prognosis.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1084
    Keywords: Key words: Bile ducts ; Calculi ; MR rapid imaging ; Stomach ; Surgery ; Noninvasive cholangiography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. In this case of choledocholithiasis in a patient with previous Billroth-II surgery and cholecystectomy we demonstrate the advantages of a heavily T2-weighted half-Fourier turbo-spin-echo (HASTE) sequence. This technique allows thin-slice snapshot imaging with 1.4 s per slice eliminating motion artifacts and still has the necessary heavy T2-weighting to depict biliary fluid with high contrast. In the presented case endoscopic retrograde cholangiography (ERCP) could not be performed prior to MRI due to technical problems. In a second attempt, ERCP was successful and a common bile duct stone as diagnosed by MRI before could be removed. We conclude that HASTE snapshot MR cholangiography can be used as a clinically valuable tool when other noninvasive methods are not diagnostic.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-2102
    Keywords: Key words Magnetic resonance tomography (MRI) • Magnetic resonance angiography (MRA) • Angiography ; Schlüsselwörter Magnetresonanztomographie (MRT) • ; Magnetresonanzangiographie (MRA) • ; Angiographie • Kontrastmittel (Gadolinium) • Abdomen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die kontrastmittelverstärkte (CE, „contrast enhanced“) Magnetresonanzangiographie (MRA) liefert hochaufgelöste Angiographien innerhalb von 20–40 s. Die Technik basiert auf der Akquisition stark T1-gewichteter dreidimensionaler (3D) Gradientenechodatensätze (FISP) mit ultrakurzen Echo- (〈 2 ms) und Repetitionszeiten (〈 5 ms) während der arteriellen Phase eines intravenös injezierten Bolus eines T1-verkürzenden Kontrastmittels wie z. B. Gd-DTPA. Für die Angiographie der Abdominalgefäße ist die CE-MRA der „time-of-flight“ (TOF) und Phasenkontrast (PC) MRA überlegen, da Bewegungsartefakte durch Aufnahmen im Atemstillstand fast vollständig vermieden werden. Wir haben die Technik der CE-MRA optimiert und ihr Potential für die Angiographie der Bauchaorta und ihrer Äste als auch des Pfortaderkreislaufs evaluiert. Während die CE-MRA im Bereich der Aorta und der proximalen Abschnitte ihrer Äste zuverlässige diagnostische Informationen liefert, können kleine, periphere Gefäße nicht zuverlässig beurteilt werden. Der Pfortaderkreislauf kann mit der CE-MRA oft besser als mit der konventionellen Angiographie beurteilt werden, ist aber, wie auch die konventionelle Angiographie, durch langsamen Fluß oder Flußumkehr behindert, Umstände, unter denen die TOF oder „true-FISP“ MRA die besten Ergebnisse liefern kann. Wir haben darüber hinaus FLASH-Echo-Planar-Imaging (EPI) Hybridtechniken untersucht, eine technische Weiterentwicklung, die auf Grund der kürzeren Aufnahmezeiten von 12–15 s die semidynamische Abbildung der arteriellen und venösen Phase ermöglicht und durch den Einsatz von Fettunterdrückung einen verbesserten Gefäßkontrast liefert.
    Notes: Summary Contrast enhanced (CE) magnetic resonance angiography (MRA) provides high resolution angiograms within 20–40 sec. The technique is based on the acquisition of heavily T1-weighted threedimensional (3D) gradient-echo data sets (FISP) with ultrashort echo- (〈 2 ms) and repetition times (〈 5 ms) during the arterial phase of an intravenously injected bolus of a T1-shortening agent such as Gd-DTPA. For MR-angiography of abdominal vessels CE-MRA is better suited than “time-of-flight” (TOF) and phase-contrast (PC) MRA because motional artifacts can be obviated with breath-held acquisitions. We have optimised the technique and evaluated its potential for angiography of the abdominal aorta and its branches as well as the portal vein and its tributaries. Whilst CE-MRA provides reliable diagnostic accuracy in the aorta and the proximal sections of its branches, small peripheral arteries cannot be assessed accurately. The portal vein and its tributaries can often be depicted better with CE-MRA than with conventional angiography but, like conventional angiography, CE-MRA is hampered by slow and reversed flow, conditions under which TOF or “true FISP” MRA may perform bst. We have also investigated FLASH-echo-planar imaging (EPI) hybrid techniques, a further technical development which due to shorter acquisition times of 12–15 sec. allows semi-dynamic imaging of the arterial and venous phase and provide better vessel contrast due to the use of fat-suppression.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Spiralcomputertomographie ; CT-Angiographie (CTA) ; CT-Subtraktionsangiographie ; Key words Spiral computed tomography ; CT-angiography (CTA) ; CT-subtraction-angiography (CTSA)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: To develop and implement a method to obtain digital subtraction (DS) spiral computed tomography angiograms (SCTA) in order to avoid superimposition of bony structures and vascular calcifications on SCTA maximum intensity projections (MIPs) and shaded surface display (SSD). Method: Two SCTA data sets, one before and one during the injection of a contrast agent bolus, were obtained with identical scan parameters. Since ordinary subtraction of the two data sets fails to reliably separate bones and calcifications from the vascular lumen because of motion, a so-called elastic subtraction procedure was designed to correct 3D misregistration between the two data sets. It automatically accommodates for local position changes between baseline and contrast images, including regionally inconsistent non-linear displacements and arbitrary rotations. This method was tested in seven patients and evaluated against ordinary DS in terms of image quality and artifacts. Results: In all patients “elastic” CTSA proved superior to ordinary DS. It provides automated and reliable separation of vessels from bones and calcifications. This improves the delineation of vessels in the neck and the skull base and of intracranial vessels. DS-SCTA facilitates MIPs and SSD without artifacts introduced by thresholding. Conclusion: Elastic DS-SCTA is a robust method for automated unmasking of vessels from bones and warrants clinical trials and comparison with MR- and conventional angiography.
    Notes: Zusammenfassung Es wurde eine Methode zur überlagerungsfreien Darstellung von Gefäßen mittels der CT-Angiographie (CTA) entwickelt und erprobt. Dazu wurde ein automatisierter, sog. „elastischer“ digitaler Subtraktionsalgorithmus entwickelt, der es ermöglicht, einen Spiral-CT-Datensatz ohne Kontrastmittel von einem solchen mit Kontrastmittel artefaktfrei zu subtrahieren. Der „elastische“ Subtraktionsalgorithmus korrigiert stochastische, transmissionsbedingte und durch Bewegung verursachte Inkongruenzen zwischen den beiden zu subtrahierenden Datensätzen und ist somit der einfachen digitalen Subtraktion überlegen. Bisher wurde die CT-Subtraktionsangiographie (CTSA) an 7 Patienten im Bereich der Hals- und intrakraniellen Gefäße erprobt. Der „elastische“ Subtraktionsalgorithmus war bei der Beurteilung von Bildqualität und -artefakten in allen Fällen und statistisch signifikant besser als die einfache digitale Subtraktion. Die „elastische“ CTSA ermöglicht eine automatisierte Trennung von ossären Strukturen und Gefäßen und erleichtert somit die überlagerungsfreie, räumliche und selektive Darstellung der Hals- und intrakraniellen Gefäße.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-2102
    Keywords: Key words Magnetic resonance imaging • magnetic resonance angiography • Contrast agents • Theory • Technique ; Schlüsselwörter Magnetresonanztomographie • Magnetresonanzangiographie • Kontrastmittel • Theorie • Technik
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die kontrastmittelverstärkte (CE: „contrast enhanced“) Magnetresonanzangiographie (MRA) ermöglicht eine qualitativ und diagnostisch hochwertige angiographische Darstellung ausgedehnter Gefäßterritorien in 20–40 sec. Voraussetzung ist die schnelle Akquisition eines dreidimensionalen Gradientenecho-Datensatzes während der Injektion eines T1-verkürzenden Kontrastmittelbolus. Wir stellen die Zusammenhänge zwischen den technologischen Parametern unterschiedlicher MR-Tomographen und der Qualität der auf ihnen realisierbaren CE-MRA dar und erörtern einige grundsätzliche Überlegungen sowie praktische Richtlinien zur Kontrastmittelinjektion.
    Notes: Summary Contrast enhanced (CE) magnetic resonance angiography affords angiographic depiction of extended vascular territories with high quality and diagnostic value. A prerequisite is the fast acquisition of a three-dimensional gradient-echo data set during the injection of a bolus of a T1-shortening contrast agent. We describe the dependence of the quality of CE-MRA on technical parameters of different MR-scanners and consider some fundamental facts and practical guidelines concerning the contrast agent injection.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-2102
    Keywords: Schlüsselwörter MRT ; Laser ; Thermotherapie ; Temperatur ; Prostata ; Key words MRI ; Laser and lasers ; Thermotherapy ; Temperature ; Prostate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: To assess the clinical value of MRI in patients with benign prostatic hyperplasia (BPH) before, during, and after interstitial laser-induced thermotherapy (LITT) of the prostate. Methods: Ten patients with symptomatic BPH had MRI examinations of the prostate 48 h before and after LITT. Online monitoring with MRI at 1.5 T of interstitial Nd:YAG laser energy deposition in the prostate was performed in two patients, repeating a T1-weighted FLASH sequence (TR 100 ms, TE 5 ms, flip angle 90 °) every 20 s. Follow-up MRI examinations 2–3 weeks, 6–8 weeks, and 6–12 months after LITT were carried out in eight patients, using T2-weighted FSE images and contrast-enhanced T1-weighted SE images. Results: The prostate was well delineated in all patients on T2-weighted FSE images, with a rather homogeneous peripheral gland and an inhomogeneous central gland. Volume measurements yielded reproducibilities of 3.2 %–4.7 %. Signal intensity in the FLASH sequence decreased during LITT, both in the prostate in vivo and in specimens of bovine prostate and seminal vesicles in vitro, with signal developments running in parallel. Areas of energy deposition and signal alteration were not sharply delineated. The latter margin of the laser-induced lesions could not be predicted from the FLASH images, while the tip of the laser fibre was easily recognized. Contrast-enhanced T1-weighted MR images immediately after LITT clearly demarcated low signal intensity laser lesions from high signal intensity surrounding prostate tissue. Follow-up examinations showed a decrease of 20 % of prostate volume over a period of 6–12 months after LITT. Correlation between prostate volume development and lesion volume alteration was 0.85–0.90 (P = 0.002–0.007) at all follow-up times. Conclusions: MRI allows rather precise recognition of intraprostatic alterations after LITT, including volume changes over a period of up to 1 year after therapy that can be predicted immediately after LITT. While laser energy deposition in the prostate can be monitored by MRI with T1-weighted FLASH sequences as a function of temperature alteration, it is not possible to determine the lesion margins immediately from the FLASH images. Online temperature development map generation will be necessary to influence ongoing LITT procedures with MRI.
    Notes: Zusammenfassung Die Magnetresonanztomographie (MRT) ermöglicht eine nicht-invasive Bestimmung von Temperaturänderungen in Proben und lebenden Geweben. Beim Monitoring der interstitiellen laserinduzierten Thermotherapie (LITT) während der Patientenbehandlung werden derzeit vor allem relativ T1-gewichtete FLASH-Sequenzen eingesetzt. In eigenen Untersuchungen bei Patienten mit benigner Prostatahyperplasie konnte mit T1-gewichteten FLASH-Sequenzen eine mit zunehmender interstitieller Energiedeposition im Prostatagewebe durch einen Nd: YAG-Laser proportional deutlich abnehmende Signalintensität um die Laserlichtleiterspitze nachgewiesen werden. Das MR-Signal nahm dabei den gleichen Verlauf wie in Proben bovinen Prostata- und Samenblasengewebes, die unter gleichen Bedingungen behandelt wurden, und kehrte nach Bestrahlungsende zur Ausgangsintensität zurück. Während die Ränder der Laserläsionsareale während der LITT in den FLASH-Sequenzen nicht sicher abgegrenzt werden konnten, waren die Läsionen unmittelbar nach LITT in kontrastverstärkten T1-gewichteten Spinechoaufnahmen als signalarme Areale klar vom signalreichen, hyperämischen Umgebungsgewebe abgrenzbar. Die Größe der gesamten Prostata und der Innendrüse konnte in T2-gewichteten TSE-Aufnahmen mit einer Reproduzierbarkeit von + / − 3,2–4,7 % bestimmt werden. Bei Nachuntersuchungen an 8 Patienten über 6–12 Monate nahmen die Volumina von Gesamt- und Innendrüse im Durchschnitt um jeweils 20 % ab. Dabei korrelierte die Volumenänderung 2–3 Wochen, 6–8 Wochen und 6–12 Monate nach Therapie stets mit Koeffizienten von 0,85–0,90 mit der Entwicklung der Laserläsionsgröße.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-2102
    Keywords: Key words Magnetic resonance imaging • Myocardial perfusion • Data evaluation ; Schlüsselwörter MR Bildgebung • Myokardperfusion • Datenauswertung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Zielsetzung: Ziel der Studie war die Erprobung einer Dreischicht Saturation Recovery Turbo FLASH Sequenz bei der Untersuchung der regionalen Myokardperfusion. Für die Datenauswertung stellen wir qualitative und quantitative Nachverarbeitungsmethoden vor, die wir an Probanden und Patienten testeten. Material und Methode: Wir untersuchten 8 gesunde Probanden und 4 Patienten mit Myokardinfarkten. Parameter der verwendeten Saturation Recovery Turbo FLASH Sequenz waren: TR = 2,5 ms, TE = 1,2 ms und α = 8°. Es wurden drei 10 mm dicke Schichten akquiriert. Zur Datenanalyse berechneten wir pixelweise Signalintensitäts-Zeit Kurven und werteten diese nach der Signalintensitätszunahme über den Ausgangswert und Signalintensitätsanstieg aus. Die Ergebnisse stellten wir farbkodiert dar. Zur quantitativen Datenauswertung nach Indikatorverdünnungstheorie entwickelten wir einen Rückfaltungsalgorithmus, der die arterielle Inputfunktion bei der Berechnung der myokardialen Mean Transit Time (MTT) berücksichtigt. Ergebnisse: Mit Hilfe der farbkodierten Parameterbilder konnten normal perfundierte von hypoperfundierte Myokardarealen gut unterschieden werden. Die mit unseres Algorithmus berechneten MTTs waren kürzer als die mit bisherigen Methoden abgeschätzten. Mit aus der Literatur ermittelten MTT Werten stimmten unsere MTTs besser überein. Infarktareale zeigten verlängerte MTTs. Schlußfolgerung: Eine Saturation Recovery Turbo FLASH Sequenz ist für die Untersuchung der regionalen Myokardperfusion in bis zu drei Schichten geeignet. Farbkodierte Parameterbilder können hypoperfundierte Myokardareale qualitativ darstellen. Für eine Berechnung der myokardialen MTT liefert ein Rückfaltungsalgorithmus verbesserte Abschätzungen der myokardialen MTT.
    Notes: Summary Purpose: Purpose of this study was to test a triple slice saturation recovery turbo FLASH sequence for myocardial perfusion imaging. In addition data-evaluation-tools for qualitative and quantitative perfusion parameters are presented and preliminary tested. Material and Methods: We examined 8 healthy volunteers and 4 patients with myocardial infarction. Parameters of the saturation recovery turbo FLASH sequence were as follows: TR = 2.5 msec, TE = 1.2 msec, α = 8 °, 3 slices, thickness 10 mm. For data analysis signal-intensity time curves were calculated pixel by pixel and evaluated for signal-intensity-increase over baseline and signal-intensity-upslope. Images were displayed color-coded. For quantitative data analysis we used the indicator dilution theory and developed a deconvolution algorithm which takes the arterial input function into account to calculate the myocardial mean transit time (MTT). Results: The color-coded parametermaps showed uniform conditions in normal myocardium of volunteers, but reduced signal-intensity-increase over baseline and signal-intensity-upslope for infarcted areas in patients. The MTTs calculated using our algorithm were significantly shorter than those assessed with previous methods and matched better with values derived from literature. Infarcted areas show prolonged MTTs in comparison to normal myocardium. Conclusion: A triple slice saturation recovery turbo FLASH sequence is suitable for myocardial perfusion imaging. Color-coded parametermaps can visualize hypoperfused areas. For calculating myocardial MTTs using indicator dilution therapy a deconvolution algorithm is necessary.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1352-8661
    Keywords: hyperfast MRI ; 3D MRI ; echo-volumar imaging
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Physics
    Notes: Abstract Echo-volumar imaging is a hyperfast technique capable of producing volumetric magnetic resonance images in times of the order of 100 ms. By increasing the gradient strengths and introducing real-time processing and display, we have been able to produce the first 16×16×16 voxel snapshot head images on volunteers.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...