Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1965-1969  (3)
  • 1969  (3)
  • 1
    ISSN: 1434-601X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Energies and yields of nuclearγ-rays accompanyingπ-mesic X-ray spectra have been measured. Theγ-lines arise either in nuclei of the atomic number of the target, or in nuclei of smaller atomic numbers. The first kind ofγ-rays are due mainly to inelastically scattered neutrons produced by pion capture in another target nucleus (secondary process), whilst the second kind are due to ordinary nuclear capture (primary process).
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1591-9528
    Keywords: Tritiumlabeled polyvinylpyrrolidon ; Ionic measuring ; Storage of foreign colloid ; Radioisotopes ; Tritiummarkiertes Polyvinylpyrrolidon ; Ionisationskammermessung ; Fremdkolloidspeicherung ; Radioisotope
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Durch die Untersuchungen mit radiomarkierter Substanz konnte die schnelle Elimination von Polyvinylpyrrolidon mit einem Molekulargewicht von 30 000 aus dem Blut, die dosisabhÄngige Ausscheidung im Stuhl und Urin ebenso wie die lÄngere Verweildauer in den Organen unter bevorzugter Ablagerung in Leber, Milz und Niere festgestellt werden. Diese Ergebnisse stimmen mit den beim Menschen durch den Tritium-PVP-Test erhaltenen Werten etwa qualitativ überein.
    Notes: Summary Investigations with tritiumlabeled PVP of a molecular weight of 30 000 show the quick elimination from the blood, the excretion in stool and urine dependent on the dosage as well as a longer storage in liver, spleen and kidneys. These results correspond to those found in human bodies subjected to Tritium-PVP-Test.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Zusammenfassung Es wird eine Methode zur analytischen und radiometrischen Bestimmung von14C-haltigem Kohlendioxid beschrieben. Das Kohlendioxid wird nach Absorption in wÄ\riger 0,1 N Bariumhydroxidlösung zunÄchst durch Rücktitration der überschüssigen Lauge mit einer Genauigkeit von 〈 ± 0,3% ermittelt. Aus dem gebildeten14C-haltigen Bariumcarbonat wird mit konz. SchwefelsÄure im Vakuum das CO2 wieder in Freiheit gesetzt und dessen spezifische AktivitÄt bestimmt. Die AktivitÄtsmessung erfolgt in einer Ionisationskammer mit einem Schwingkondensatorelektrometer. Der mittlere Fehler des Mittelwertes der AktivitÄtsbestimmung betrÄgt ± 0,5%.
    Notes: Abstract After absorption in an aqueous solution of 0.1 N barium hydroxide the carbon dioxide is determined with an accuracy of ± 0.3% by back titration of the excessive base. From the14C containing barium carbonate formed the carbon dioxide is liberated again with cone, sulphuric acid in vacuo, and its specific activity is determined. The measurement of activity is performed with a vibrating reed electrometer in an ionization chamber. The mean error of the average value of the activity determination is ± 0.5%.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...