Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0932
    Keywords: Rachis dégénératif ; Fusion lombaire ; Ostéosynthèse ; Vissage translamaire des facettes ; Degenerative spine ; Lumbar fusion ; Internal fixation ; Translaminar facet screw
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary From 1984 to 1988, 70 consecutive lumbar and lumbosacral spine fusions enhanced with translaminar facet joint screws were performed for segmental degenerative disease. Twenty patients had partial decompression of central stenosis, 15 concomitant discectomy, and 19 lateral nerve root decompression. The mean time to fusion was 4.5 months (range 2–7 months). At follow-up (average 45 months; range 24–74 months) 98.5% were judged to have solid fusion. Satisfactory results were observed in 84% of cases, 91% without previous surgery and 75% after previous discectomy. Supplementation of posterolateral fusion by translaminar facet screws significantly improved time to fusion, fusion rate, and clinical outcomes with no significant increased complications.
    Notes: Résumé De 1984 à 1988, 70 arthrodèses lombaires et lombo-sacrées renforcées par un vissage translamaire des articulations interapophysaires ont été réalisées consécutivement pour des atteintes dégénératives segmentaires du rachis. Vingt patients ont eu dans le m^eme temps une décompression partielle pour sténose centrale, 15 une discectomie et 19 une décompression radiculaire latérale. Le délai moyen de fusion a été de 4,5 mois (valeurs extrêmes: 2–7 mois). A distance (délai moyen: 45 mois; valeurs extrêmes: 24–74 mois), 98,5% des patients présentaient une fusion stable. Les résultants satisfaisants ont été globalement observés dans 84% des cas, dans 91% des cas sans chirurgie préalable et dans 75% des cas après discectomie préalable. Le renforcement de la greffe postéro-latérale par le vissage translamaire des facettes améliore de manière significative de délai et le taux de fusion ainsi que les résultats cliniques, sans augmentation significative du taux des complications.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0932
    Keywords: Discographie ; Discomanométrie ; Disque intervertébral. Rachis lombaire ; Key words ; Discography ; Discomanometry ; Intervertebral disc ; Lumbar spine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary A new discomanometry system was developed and evaluated for application in the lumbar spine. The diagnostic reliability of discography, manometry and discomanometry (a combination of both methods) was assessed in 20 lumbar cadaver spines (95 intervertebral discs) with regard to the diagnosis of non-contained intervertebral discs. The sensitivity was 92% for manometry and 78% for discography. This indicates that 22% of the non-contained discs could not be correctly identified with common discography. The specificity was 98% for manometry and 100% for discography, indicating that contained discs could be easily identified with both methods. A combination of manometry and discography provides a high sensitivity (98%) as well as high specificity (98%). It is concluded that discomanometry is a simple, cost-effective and reliable diagnostic procedure which can precede percutaneous nucleotomy without additional risks or relevant efforts. It allows the differentiation between contained and non-contained intervertrebral discs with a high degree of diagnostic reliability in an experimental setting, which justifies its further application in patients.
    Notes: Résumé Un nouveau système de discomanométrie a été développé et évalué afin d'être appliqué au rachis lombaire. La fiabilité diagnostique de la discographie, de la manométrie et de la discomanométrie (combinaison des deux méthodes) en matière de hernie discale, a été évaluée sur 20 rachis lombaires de cadavres (95 disques intervertébraux). La sensibilité était de 92% pour la manométrie et 78% pour la discographie. Cela indique que 22% des disques présentant une hernie ne pouvaient pas être identifiés par la discographie de routine. La spécificité était de 98% pour la manométrie et 100% pour la discographie, indiquant que les disques intacts pouvaient être aisément identifiés par les deux méthodes. Une combinaison de la manométrie et de la discographie assure une grande sensibilité (98%) ainsi qu'une haute spécificité (98%). En conclusion, la discomanométrie est un procédé diagnostique simple, économique et fiable que l'on peut pratiquer avant la nucléotomie percutanée sans risques ni efforts supplémentaires importants. Elle permet de distinguer les disques intervertébraux intacts des disques rompus avec une grande fiabilité diagnostique expérimentale, ce qui justifie son utilisation chez les patients.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1434-601X
    Keywords: 35.10.F ; 21.10
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The hyperfine structure, isotope and isomeric shifts in the atomic transition 6p 2 P 3/2−7s 2 S 1/2, λ=535 nm have been measured for theI=7 andI=2 states of190, 192, 194, 196Tl; theI=1/2 andI=9/2 states of191Tl and the I=7 isomer of188Tl. The thallium isotopes were prepared as fast atomic beams at the GSI on-line mass separator following fusion reactions and — in some cases — subsequentβ-decay. The nuclear dipole moments, electric quadrupole moments and the change in the nuclear mean square charge radius are evaluated. Theuu-isotopes show an isomeric shift which changes sign between192Tl and194Tl.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...