Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1420-9136
    Keywords: Monsoon ; Effect on angular momentum, effect on kinetic energy ; Tropical general circulation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract The balance conditions of relative angular momentum and time-mean kinetic energy and their annual variations are studied for the Northern Hemisphere tropical belt. The belt is divided into two roughly equal size parts, the monsoon and the extramonsoon regions. The data used consist of all available daily rawinsonde reports from the world areological network for the two 5-year periods 1958–63 and 1968–73. In winter, the trade winds in the monsoon and extramonsoon regions are both sources of westerly relative angular momentum for the middle latitude circulation. However, it is found that the angular momentum gained in the extramonsoon region of the Tropics is mostly destroyed by a net southward flow of mass in that region, and becomes regenerated in the monsoon region by a net northward flow of mass there. This excess of angular momentum together with the angular momentum picked up locally in the monsoon region is almost all exported across its northern boundary. It is further found that in winter the Tropics are also an important source of mean kinetic energy for middle latitudes. Again almost all export of kinetic energy was found to take place across the northern boundary of the monsoon sector. Most of this energy must be generated through the pressure gradient term inside the monsoon region itself, the transformation from transient eddy kinetic energy being very small. The proper evaluation of the pressure gradient appears to be the main stumbling block in the present study, preventing us from estimating the generation and thereby, as a residual, the frictional dissipation in the two regions. In summer, the extramonsoon region remains a source of angular momentum, but the monsoon region with its surface westerlies acts as a sink, leading to a sharp reduction (and even a midsummer reversal) of the export into middle latitudes. Also the export of mean kinetic energy almost vanishes in summer, except for a small southward transfer across the equator. The calculations for two 5-year periods give very similar estimates and thereby show the reliability of the results.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1618-2650
    Keywords: Best. von Sulfat ; Photometrische Titration ; Automatische Korrektur für Trübung u. Verdünnung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary Turbidity in a titration solution or dilution upon sample introduction causes systematic errors in automatic Spectrophotometric set-point titrations. The reduction of these errors with a factor of about 10 is realized by subtracting the signals of two light beams of different wave length which pass the same titration solution. The signal values both depend on the absorption of coloured substances (indicator) and on turbidity or dilution effects. Assuming that these effects are independent of the wave length and selecting wave lengths at which indicator absorbance differs greatly, subtraction of the signals leads to the elimination of said effects. As an illustration nMole amounts of sulphate were titrated in 80–90% aceton with a lead(II)-titrant using dithizone as indicator. The standard deviation was about 2%. A titration took 1–2 min.
    Notes: Zusammenfassung Trübung einer Titrationslösung oder Verdünnung nach Probe- oder Titrantzugabe verursacht systematische Fehler bei automatischen spektralphotometrischen Titrationen bis zum vorgewählten Endpunkt. Es zeigte sich die Möglichkeit, diese Fehler zehnfach zu verkleinern durch Abziehen der Signale zweier unterschiedlich gefärbter Lichtbündel, die beide durch die Titrationslösung gehen. Die Signalwerte hängen von der Absorption gefärbter Substanzen (Indicator) und von den Trübungs- und Verdünnungseffekten ab. Wenn diese unabhängig von der Wellenlänge sind, und wenn die Lichtabsorption der Lösung in den beiden Bündeln verschieden ist, führt eine Subtraktion zur Eliminierung der genannten Effekte. In einem Beispiel werden nMole Sulfat in 80–90% Aceton mit Blei(II)- Lösung und Dithizon als Indicator titriert. Die Standardabweichung beträgt etwa 2%, die Dauer einer Titration 1–2 min.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1618-2650
    Keywords: Best. von Zink ; Photometrische Titration ; Anw. der Regelungstechnik
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary As a result of a control engineering approach a set-up with controller is developed, which enables to carry out a subtraction photometric titration [2,3] within about 5 s. The method is illustrated with the determination of 1–5 nMole of Zn. The accuracy is better than 3–5% Zn rel. Some further suggestions are given for increasing the speed of a titration.
    Notes: Zusammenfassung Die Anwendung der Regelungstechnik ermöglichte die Entwicklung einer Vorrichtung mit Regler, die im Stande ist, eine subtraktionsphotometrische Titration [2,3] in etwa 5 s durchzuführen. Die Methode wird an Hand der Bestimmung von 1–5 nMol Zn beschrieben. Die Genauigkeit ist besser als 3–5% Zn rel. Auf weitere Möglichkeiten zur Verkürzung der Dauer einer Titration wird hingewiesen.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1618-2650
    Keywords: Photometrische Titration ; Automatische Korrektur für Trübung u. Verdünnung, Verbesserung des Systems
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The optical part of the subtraction dual-wavelength spectrophotometric titration device [1– 3] was simplified by extension of the mechanical and electronical parts. Owing to this, the reliability of the device was improved and the sensitivity to changing parameters was strongly diminished. The two light beams have been replaced by one, filtered intermittently by two light-filters fixed in a rapidly rotating disc. The broader light-beam used was focused on one phototransistor after having passed the cuvette. A good synchronization was needed. The accuracy of the titration was not affected by these alterations.
    Notes: Zusammenfassung Der optische Teil der früher beschriebenen [1–3] Vorrichtung zur spektrophotometrischen Titration mit zwei unterschiedlich gefärbten Lichtbündeln wurde durch Erweiterung des mechanischen und elektronischen Teils vereinfacht. Hierdurch wurde die Zuverlässigkeit erhöht und die Empfindlichkeit vor ändernden Parametern stark reduziert. Die zwei Lichtbündel wurden von einem weißen Bündel ersetzt. Mit zwei Filtern auf einer schnell drehenden Scheibe werden dann die zwei Signale erhalten. Das Lichtbündel war breiter und wurde nach dem Durchgang durch die Küvette auf einen Phototransistor fokussiert. Eine gute Synchronisation war notwendig. Die Genauigkeit des Titrationsverfahrens wurde von den Änderungen nicht beeinflußt.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1618-2650
    Keywords: Best. von Zink ; Photometrische Titration ; Automatische Korrektur für Trübung und Verdünnung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A refined correction of the described [4] method to corrigate for systematic errors due to turbidity and dilution is necessary, if these errors should exceed 10%. This refinement consists of a correction for the difference in the relative spectral sensitivity of the detectors and for the particle size and wave length dependent light scattering. One of the signals is exponentially transformed before being subtracted (s. part I). Thus in practice a refinement of an other 10% was readily obtainable. As an illustration about 1 nMole of Zn(II) is chelatometrically titrated in slurries of SnO2 and BaSO4 (coarse particles) and SiO2 (fine particles). The indicator used was xylenol orange. A standard deviation of about 1–2 % was found. The titration took 1–2 min.
    Notes: Zusammenfassung Es wird eine Verfeinerung des beschriebenen [4] Verfahrens zur Korrektur systematischer Fehler, aus Trübung und Verdünnung herrührend, beschrieben, die es ermöglicht, Fehler größer als 10% zu korrigieren. In dieser Verfeinerung wird korrigiert für den Unterschied in relativer Spektralempfindlichkeit der beiden Detektoren und für die Abhängigkeit der Lichtzerstreuung der Teilchengröße und der Wellenlänge des Lichts. Eines der Signale wird vor Subtrahierung exponentiell transformiert (s. Teil I). In dieser Weise ist in der Praxis eine weitere Verfeinerung von 10% leicht erreichbar. Als Beispiel wird die komplexometrische Titration von Zn(II) in Suspensionen von SnO2 und BaSO4 (grob) und SiO2 (fein) beschrieben. Der Indicator war Xylenol-orange. Eine Standard-Abweichung von 1–2% wurde gefunden. Die Titrationsdauer war 1–2 min.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1618-2650
    Keywords: Best. von Calcium in Harn ; Photometrische Titration ; automat. Korrektur für Trübung und Verdünnung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An automatic set-point titration with subtraction-photometric detection is used to determine Ca in turbid urine samples. The titration is carried out with EGTA at a pH of 8.5. The set-point solution contains the Zn-EGTA complex and zincon. Upon addition of Ca ions, Zn ions are set free, which are back-titrated till the original equilibrium situation is restored. Analyses of μl-amounts of urine gave standard deviations of 2–3% rel. The recovery was 100% (150–400 mg/l). A titration took about 2 min making possible 200 analyses per day. The exponential transformation showed to be necessary for the analysis of turbid samples.
    Notes: Zusammenfassung Eine automatische Titration mit vorgewähltem Endpunkt und mit subtraktions-photometrischer Detektion wurde zur Bestimmung von Calcium in trüben Harnproben angewendet. Die Titration wird mit ÄGTA bei einem pH-Wert von 8,5 vorgenommen. Die Endpunktslösung enthält Zn-ÄGTA-Komplex und Zinkon. Calciumionen aus der Probe setzen Zn(II) frei. Es wird mit ÄGTA titriert bis zum Anfangsgleichgewicht. Die Standardabweichung bei der Analyse von Proben von einigen μl war ungefähr 2–3 % rel. Der gesamte Ca-Gehalt wurde zu 100% erfaßt (Bereich 150–400 mg/l). Die Titrationsdauer beträgt ungefähr 2 min; täglich können 200 Analysen ausgeführt werden. Für trübe Harnproben war eine exponentielle Transformation notwendig.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1618-2650
    Keywords: Anwendung der Regelungstechnik ; Chemische Analyse ; Durchflußsystem
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An experimental set-up of a coulometric titration with spectrophotometric indication in a flowthrough cell is developed. A mathematical model of this system is found by experiments and checked with the real system. This model gave rise to a controller design. This controller inserted in the real system enables titration times of 10 s for a titration of a few neq. of acid in an on-line system. These titration times may be further decreased by some relative simple geometric improvements of the glass cell used.
    Notes: Zusammenfassung Eine coulometrische Titration mit spektralphotometrischer Endpunktanzeige im Durchfluß-system wurde entwickelt. Ein mathematisches Modell wurde experimentell ausgearbeitet und an Hand des Titratorsystems überprüft. Mit Hilfe dieses Modells wurde eine Steuerung entwickelt. Diese ist in dem Titrator eingebaut und ermöglicht eine Titrationsdauer von 10 s bei der Titration von nÄq.-Mengen Substanz. Die Titrationsdauer kann durch relativ einfache geometrische Änderungen der Glas-Durchflußzelle noch verkürzt werden.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1618-2650
    Keywords: Chemische Analyse, Coulometrie, Potentiometrie ; Anw. der Regelungstechnik
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A reliable model of a potentiometric pH set-point coulometric titration is found using different test signals. This model includes an extra parallel path illustrating non-chemical influences between measuring and detecting circuits. Using this model a controller is found and tested, resulting in a titration time of 12 s. An even faster titration is possible when a constant systematic error is accepted.
    Notes: Zusammenfassung Ein Modell einer potentiometrisch indizierten coulometrischen Titration wird an Hand von Messungen an einem öfter benutzten Titrationssystem erörtert. Aus diesem Modell, in das ein aus Messungen hervorgegangener Parallelweg aufgenommen wurde, wurde eine Regelung entwickelt, die eine Titration in 12 s ermöglicht. Die Titration kann noch schneller durchgeführt werden, wenn man einen konstanten systematischen Fehler in Kauf nimmt.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1618-2650
    Keywords: Best. von Chlorid ; Coulometrische Titration ; TFA statt Essigsäure
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1618-2650
    Keywords: Photometrische Titration ; subtraktionsphotometr. Gerät, regelungstechn. Untersuchung
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary A single beam subtraction photometric titration device [4] was investigated with control engineering methods to establish its static and dynamic properties. Using an appropriate controller, titrations of Zn(II) in the nMole range with EDTA and xylenol orange as an indicator were carried out within 3–5 s. The rates of the several chemical reactions had to be considered.
    Notes: Zusammenfassung Das Subtraktions-photometrische Titriergerät mit einem Lichtbündel [4] wurde mit Methoden aus der Regelungstechnik untersucht, um die statischen und dynamischen Eigenschaften zu ermitteln. Mit einem geeigneten Regler konnten Titrationen von Zn(II) im nMol-Gebiet mit ÄDTA und Xylenol-Orange als Indicator innerhalb von 3– 5 s ausgeführt werden. Die Geschwindigkeit unterschiedlicher chemischer Reaktionen mußte berücksichtigt werden.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...