Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1955
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1955
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Description / Table of Contents: Zusammenfassung Nach vierstündiger in vitro-Inkubation von Hymenolepis diminuta in Gegenwart des Bandwurmmittels Terenol (chem. Kurzbezeichnung: Resorantel) wurden in den Zestoden die Aktivitäten einiger Glykolyseenzyme und die Konzentration intermediärer Stoffwechselprodukte bestimmt. Resorantel verursacht ein Absinken der ATP-, ADP- und Glykogenkonzentrationen sowie eine gleichzeitige Erhöhung der AMP- und Pyruvatspiegel. Die Befunde weisen auf einen Block im Endabbau der Glukose und auf eine daraus resultierende Störung des Energiestoffwechsels als Ursache der zestodiziden Präparatwirkung hin. Als primärer Angriffsort wird eine Hemmung der Fumaratreduktase diskutiert. Resorantel hemmt außerdem in Mitochondrienfraktionen aus Hymenolepis diminuta den Sauerstoffverbrauch.
    Notes: Summary The activities of some glycolytic enzymes and the concentrations of several metabolic intermediates in Hymenolepis diminuta have been evaluated following a 4-hour period of in vitro incubation in the presence of Terenol (generic name: Resorantel), a tapeworm remedy. Resorantel causes a decrease in ATP-, ADP- and glycogen concentrations as well as a simultaneous increase in AMP- and pyruvate levels. These findings indicate a block of the final steps of glucose decomposition and hence an impaired energy metabolism as the cause of the cestodicide drug action. An inhibition of the fumarate reductase as the primary site of action is discussed. Resorantel also inhibits oxygen consumption in mitochondrial preparations isolated from Hymenolepis diminuta.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Es wird von den bei Durchführung der Schrittmacher therapie mit einem standardisierten Verfahren an einer größeren Gruppe von Patienten beobachteten Spätkomplikationen berichtet. Die mit einer Frühkomplikationsrate von 15% behaftete Prozedur der Verlegung einer Elemaelektrode hat eine Spätkomplikationshäufigkeit von 5–8%. In etwa der gleichen Größenordnung treten Spätkomplikationen im Bereich der Schrittmachertasche ein, deren Gesamtzahl aber wesentlich höher ist, da durchschnittlich 3 Schrittmacher zu einer Elektrode im plantiert werden. Schätzungen ergeben, daß etwa 8% der Schrittmacherpatienten eine lebensgefährliche Komplikation zu erwarten haben.
    Notes: Summary Heart-pacemaker therapy is performed in a group of patients after a standardized protocol. Incidence and type of late complications are reported. The procedure of placing an intracardiac Elema electrode is followed by 15% early and 5–8% late complications. As frequently, late complications of the pacemaker pocket are seen, the total number of these ranging much higher, as on average 3 pacemakers are implanted for 1 electrode. Estimations show that every fourth patient will have a complication during his life time and that this will be life-threatening in 8% of all patients.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Microchimica acta 30 (1942), S. 269-272 
    ISSN: 1436-5073
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-2451
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die Funktion implantierter Schrittmacher, insbesondere von synchronisierbaren Modellen, kann durch elektromagnetische Felder oder galvanische Berührung mit dem Versorgungsnetz entscheidend beeinfluß werden, so daß bei Nichtbeachtung für den betroffenen Patienten lebensbedrohliche Zustäde auftreten können. Als potentielle Störquellen müssen daher alle netzbetriebenen Haushaltsgeräte, Werkzeugmaschinen and öffentliche Verkehrsmittel, sowie Radarstationen, Mikrowellengeräte und Zündanlagen angesehen werden. Dabei sind solche Geräte besonders zu beachten, die mit Stromrichtern zur Leitstungssteuerung ausgerüstet sind. Das elektromagnetische Feld einer Störquelle wirkt cinerseits kapazitiv auf die Schrittmacherschaltung, die wegen der hochohmigen Bauelemente besonders empfindlich ist. Andererseitsbilden die Elektroden des künstlichen Reizsystems Antennen, so daß alle Störanteile, die mit dem Frequenzbereich des Verstärkers übereinstimmen, die Funktion der Schrittmacherschaltung beeinflussen können und es zum Ausfall der Synchronisation, zur Blockierung der Stimulation oder zu einer gefährlichen Erhöhung der Stimulationsfrequenz kommen kann. Grundsätzlich gilt, daß der unsynchronisierte Herzschrittmacher gegen elektromagnetische Storungen relativ unempfindlich ist, insbesondere lassen geeignete Abschirmungsmaßnahmen die kapazitive Einkoppelung der Störungen vermeiden. Bei synchronisierbaren Geräten verschiedener Hersteller ergaben die vergleichenden Untersuchungen stets eine gewisse Störempfindlichkeit. Durch Mesungen an Störnormalen nach internationalen Empfehlungen und durch Vergleich mit den zulässigen Feldstärken wurde die Störempfindlichkeit von synchronisierbaren und festfrequenten Schrittmachern untersucht. Die Messungen erfolgten unter Bedingungen, wie sie imimplantierten Zustand vorliegen. Die Meßergebnisse beweisen, daß zwischen den einzelnen Fabrikaten erhebliche Unterschiede bestehen. In vielen Fällen ist die Störempfindlichkeit wesentlich größer. als sie auf Grund der Schaltungsanordnung notwendig wäre. Hierbei ist der Haupteinfluß auf die kapazitive Einkopplung der Störung in die Schaltung zurückzuführen. Besonders vorteilhaft schnitten die Fabrikate ab, bei denen durch metallische Einkapselung der Schaltung kapazitive Einstreuung vermieden werden konnte.
    Notes: Summary The function of implanted pacemakers, especially of synchronisable models, can be decisively affected by electromagnetic fields or galvanic contact with the supply mains, so that in case of lack of attention life-threatening situations may arise. Therefore all mains-operated household equipment, machine tools and public transport as well as radar stations, microwavesets and ignition devices must be regarded as potential sources of interference. Special care must be taken with devices equipped with rectifiers for output regulation. The electromagnetic field of a source of interference acts, on the one hand, on the capacity of the pacemaker circuit which is particularly sensitive because of its high-resistance parts, and, on the other hand, the electrodes of the artificial stimulation system form antennae so that all interference within the frequency range of the amplifier can affect the function of the pacemaker circuit and cause a loss of synchonisation, blockage of stimulation or a dangerous rise of stimulation frequency. In any case, the unsynchronised cardiac pacemaker is ralatively insensitive to electromagnetic interference, more particularly, sutitable screening can prevent capacity interference. In synchronisable devices of various manufacturers comparative tests always showed a certain sensitivity to inteference. The sensitivity of synchronisable and fixed frequency pacemakers was examined according to international recommendations by measurements on those with normal interference and by comparison with admissible field intensities. The measurements took place under conditions as present after implantation. The results prove that there are considerable differences between the different makes. In many cases the interference sensitivity is considerably higher than would be necessary with the particular circuit arrangement. The main effect is here due to the interference with capacity in the circuit. Those models came out best in which capacity interference was prevented by metallic enclusure of the circuit.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Solar physics 28 (1973), S. 233-246 
    ISSN: 1573-093X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Solar neutron emission during large flares is investigated by using neutron monitor data from the mountain stations Chacaltaya (Bolivia), Mina Aguilar (Argentine), Pic-du-Midi (France) and Jungfraujoch (Switzerland). Registrations from such days on which large flares appeared around the local noon time of the monitor station are superimposed with the time of the optical flare as reference point. No positive evidence for a solar neutron emission was found with this method, However, by using an extrapolation of the neutron transport functions given by Alsmiller and Boughner a rough estimation of mean upper limits for the solar neutron flux is possible. The flux limits are compared with Lingenfelter's model calculations. From the Chacaltaya measurements it follows: N 0⩽2.8 × 10−3 N cm−2 s−1 per proton flare, E 〉 50 MeV, if P0 = 125 MV N 0⩽1.4 × 10−2 N cm−2 s−1 per proton flare, E 〉 50 MeV, if P 0 = 60 MV and from Pic-du-Midi measurements: N 0⩽6.7 × 10−3 N cm−2 s−1 per proton flare, E 〉 50 MeV, if P 0 = 125 MV N 0⩽4 × 10−2 N cm−2 s−1 per proton flare, E 〉 50 MeV, if P 0 = 60 MV P 0 = characteristic rigidity of the producing proton spectrum on the Sun. The flux limits estimated for some special proton flares are consistent with Lingenfelter's predictions for the acceleration phase but are too small for the slowing down phase. Therefore it is believed that Lingenfelter's assumption of isotropic proton emission from the flare region is not fulfilled.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1573-093X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract Solar proton fluxes observed with the satellites Azur, Explorer 41, and Explorer 35 as well as interplanetary magnetic field measurements obtained by Explorer 35 are used to study the transport processes of low energy protons. The experimental results are compared with several authors' theories. The influence of diffusion, convection, collimated convection and scatter-free propagation is discussed as well as propagation close to the Sun. In most cases the anisotropy vectors are field aligned during the rise and decay phase of the events. However, large scale directional discontinuities of the interplanetary magnetic field can decouple the anisotropy vectors from the field directions and determine the phases in which collimated convection and convection with the solar wind dominates. Three extreme western limb events give evidence for propagation of solar protons close to the Sun and anisotropic diffusion in the interplanetary space.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Parasitology research 34 (1970), S. 22-23 
    ISSN: 1432-1955
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Parasitology research 42 (1973), S. 137-145 
    ISSN: 1432-1955
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Description / Table of Contents: Zusammenfassung Die Empfänglichkeit von Meriones unguiculatus gegenüber Nippostrongylus muris steht in Abhängigkeit vom Alter des Wirtes. Besonders empfänglich sind 4–6 Wochen alte Tiere; bereits 〈200 Larven führten bei 6 von 12 Meriones zum Exitus. 18 Monate alte Tiere vertrugen 800 Larven ohne klinische Erscheinungen. 136 Std nach der Infektion wurden erstmals Eier von Nippostrongylus muris im Kot nachgewiesen. Die Maxima in der Eiausscheidung ergaben sich am 7. bzw. 8. Tag p.i. Am 14. Tag nach der Infektion waren alle Meriones koprologisch negativ; zu diesem Zeitpunkt ist die Elimination der Parasiten so gut wie abgeschlossen. In der Lunge waren 12 Std p.i. die ersten Larven nachweisbar mit einem 40 Std p.i. erreichten Maximum. Fünf Passagen von Nippostrongylus muris in Meriones hatten eine Virulenzsteigerung zur Folge. Dagegen kam es bei Ratten nach Rückinfektion zur Abschwächung der Virulenz. Nach einer Zweit- und Drittinfektion waren Meriones unguiculatus weitgehend immun. Histologisch ließen sich 7 Tage nach der Drittinfektion Entwicklungsstadien in der Lunge nachweisen.
    Notes: Summary The susceptibility of Meriones unguiculatus to Nippostrongylus muris depends on the age of the host. Four to six-week-old animals are particularly susceptible: infection with as few as 〈200 larvae resulted in the death of 6 out of 12 Meriones. Eighteen-month-old animals tolerated 800 larvae without showing any clinical manifestations. The first eggs of Nippostrongylus muris were detected in the feces 136 h after infection. Maximum egg output was seen on the 7th and 8th day, respectively, after infection. Coprological examination was negative on the 14th day after infection in all Meriones; at that time elimination of the parasites is practically complete. Twelve hours after infection the first larvae were detectable in the lungs, the maximum being reached 40 h after infection. The virulence of Nippostrongylus muris had increased after five passages in Meriones (Table 3). In contrast, the virulence in rats had subsided after re-infection (Table 4). Meriones unguiculatus were largely immune after a second and third infection. Seven days after the third infection developmental stages of the parasites could be detected in the lungs on histological examination.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0800
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...