Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (1)
  • 1920-1924  (1)
Collection
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Lung 54 (1923), S. 1-110 
    ISSN: 1432-1750
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Schlußbetrachtung Die vorstehend mitgeteilten, durch den Krieg leider vorzeitig abgebrochenen Versuche haben eineendgültige Lösung des Problems der Typenumwandlung der Tuberkelbacillennicht gebracht. Sie haben aber gezeigt, daß die für die Typentrennung bisher benutzten biologischen Unterscheidungsmerkmale (Wachstum der frisch aus dem Tierkörper gezüchteten Reinkulturen auf Glycerinbouillon, Verhalten bei Kaninchen- und Rinderimpfungen) mit Hilfe der angewandten Methodik in einzelnen Fällen im Sinne einer allmählichenAnnäherung der beiden Säugetier-Tuberkelbacillentypen beeinflußt werden konnten.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A novel design for an airborne NOy converter was implemented, characterized in the laboratory, and used extensively for in situ tropospheric and stratospheric measurements of total reactive nitrogen (NOy). During field deployments, the converter is mounted outside the aircraft fuselage, avoiding the need for an inlet line. In flight, the converter can be calibrated by the addition of standard gases close to the sample inlet, compensating for any changes in the instrument sensitivity caused by changing operating conditions. The system has been used successfully during several Stratosphere Troposphere Experiments by Aircraft Measurements campaigns in the lowermost stratosphere and upper troposphere for the measurement of total reactive nitrogen. The detection limit of the system is approximately 100 pptv for 10 s integrated data (2σ). The precision, deduced from the reproducibility of the in-flight calibrations, is 7% and the accuracy is about 30%. Laboratory studies demonstrate that interference from HCN, NH3, and CH3CN is negligible for background conditions. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...