Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • DIAGNOSIS  (1)
  • TIME  (1)
  • 1
    Keywords: CANCER ; tumor ; MODEL ; THERAPY ; DIAGNOSIS ; MRI ; magnetic resonance imaging ; PERFORMANCE ; EXPERIENCE ; prostate cancer ; FUSION ; BIOPSY ; GUIDANCE ; three-dimensional imaging ; GUIDED BIOPSY ; MAPPING BIOPSY ; TRUS
    Abstract: Background. A key challenge for prostate cancer (PC) therapy is to exactly diagnose tumor lesions. In this context we describe a new stereotactic prostate biopsy system, which integrates pre-interventional MRI with peri-interventional ultrasound for targeted perineal prostate biopsies. Furthermore, the novel system allows exact documentation of biopsies in three dimensions. Patients and methods. Stereotactic biopsy was performed in 50 consecutive men with suspicion of PC [median age 67 years (42-77), mean PSA 8.9 +/- 6.8 ng/ml, and mean prostate volume 51 +/- 23.7 ml]. Twenty-five of these patients (50%) had already had a negative transrectal ultrasound (TRUS)-guided biopsy. All men underwent multiparametric, contrast-enhanced 3T MRI without endorectal coil. Suspicious lesions were marked before the obtained data were transferred to a novel stereotactic biopsy system. Using a custom-made biplane TRUS probe mounted on a stepper, 3-D ultrasound data were generated and fused with the MRI. As a result, suspicious MRI lesions were superimposed onto the TRUS data. Next, 3-D biopsy planning was performed including systematic biopsies from the peripheral zone of the prostate. According to local standards patients were treated with perioperative quinolone antibiotics and applied a rectal enema the evening before the procedure. Perineal biopsies were taken under live US imaging, and the location of each biopsy was documented in an individual 3-D model. Feasibility, safety, target registration error, and cancer detection were evaluated. Results. The median number of biopsies taken per patient was 24 (12-36). In 27 men of the initial cohort of 50 consecutive patients presented here, biopsy samples showed PC (54%). In patients undergoing their first biopsy, cancerous lesions were diagnosed in 13 of 19 patients (68%). The result was positive in 36% of men undergoing a re-biopsy without previous cancer diagnosis (9/25). A positive correlation between MRI findings and histopathology was found in 72%. In MRI lesions marked as highly suspicious, the tumor detection rate was 100% (13/13). Looking at single cores from highly suspicious lesions, 40 of 75 (53%) biopsies were positive. The target registration error of the first 1,159 biopsy cores was 1.7 mm. Regarding adverse effects, one patient experienced urinary retention and one patient a perineal hematoma. Urinary tract infections did not occur. Conclusion. Perineal stereotactic prostate biopsies guided by the combination of MRI and ultrasound allow effective examination of suspicious MRI lesions. Each biopsy core taken is documented accurately for its location in 3-D enabling MRI validation and tailored treatment planning. The morbidity of the procedure was minimal
    Type of Publication: Journal article published
    PubMed ID: 21935634
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    Keywords: CANCER ; THERAPY ; TIME ; MRI ; PERFORMANCE ; EXPERIENCE ; GUIDANCE ; GUIDED BIOPSY ; PATIENT SELECTION ; MAPPING BIOPSY
    Abstract: PURPOSE: We developed an effective way to precisely diagnose prostate cancer using a novel prostate biopsy system that integrates pre-interventional magnetic resonance imaging with peri-interventional ultrasound for perineal navigated prostate biopsy. MATERIALS AND METHODS: A total of 106 men with findings suspicious for prostate cancer (median age 66 years, prostate specific antigen 8.0 ng/ml and prostate volume 47 ml) underwent multiparametric 3 Tesla magnetic resonance imaging. Suspicious lesions were marked and data were transferred to the novel biopsy system. Using a custom-made biplane transrectal ultrasound probe mounted on a stepper we gathered 3-dimensional ultrasound data and fused them with magnetic resonance imaging data. As a result, suspicious magnetic resonance imaging lesions were superimposed over the transrectal ultrasound data. Three-dimensional biopsy planning was done, including systematic biopsies. Perineal biopsies were taken under live ultrasound guidance and the precise site of each biopsy was documented in 3 dimensions. We evaluated feasibility, safety and cancer detection. RESULTS: Prostate cancer was detected in 63 of 106 patients (59.4%). Magnetic resonance imaging findings correlated positively with histopathology in 71 of 103 patients (68.9%). In magnetic resonance imaging lesions marked as highly suspicious, the detection rate was 95.8% (23 of 24 cases). Lesion targeted cores had a significantly higher positivity rate than nontargeted cores. The procedural targeting error of the first 2,461 biopsy cores was 1.7 mm. Regarding adverse effects, 2 patients experienced urinary retention and 1 had a perineal hematoma. Urinary tract infections did not develop. CONCLUSIONS: Perineal stereotactic prostate biopsies guided by the combination of magnetic resonance imaging and ultrasound enable effective examination of suspicious magnetic resonance imaging lesions. Each biopsy core taken is documented accurately for its location in 3 dimensions, enabling magnetic resonance imaging validation and tailored treatment planning. The morbidity of the procedure was minimal.
    Type of Publication: Journal article published
    PubMed ID: 22014798
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...