Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • POLY-MESAM  (2)
  • Springer  (2)
  • German Medical Science; Düsseldorf, Köln
  • 1
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schlafapnoe ; Ambulante Polygraphie ; POLY-MESAM ; Key words Sleep apnea ; Ambulatory recording units ; POLY-MESAM
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: For some time, the ambulatory diagnosis of respiratory disturbances during sleep has included the use of seven-channel recording units. One of these systems is the POLY-MESAM unit (MAP, Germany). Methods: The aim of the present study was to validate the POLY-MESAM system by simultaneously performing 12-channel polysomnography. Forty-nine patients (45 males and 4 females) with different severities of obstructive sleep-related breathing disorders were included. Obstructive sleep apnea was diagnosed, when an apnea-hypopnea index (AHI) 〉15 was found by polysomnography. The sensitivity and specificity for POLY-MESAM were calculated on the basis of the polysomnographic AHI. Results: The sensitivity of POLY-MESAM for detecting patients with an AHI 〉15 was 86.4% and the specificity was 100%. Conclusions: The POLY-MESAM system was easy to use. The sensitivity and specificity for the MESAM4 unit were 92% and 97% respectively, which was similar to POLY-MESAM. Additionally, POLY-MESAM provided the possibility for distinguishing the different kinds of apneas. Thus, POLY-MESAM was considered to be a useful development of the previous MESAM4 unit. In some cases, use of the POLY-MESAM unit resulted in underestimation of the AHI. POLY-MESAM produced false-negative results in patients with mild to moderate OSA. This finding was reflected in the relatively poorer sensitivity of the method (86.4%). Cardiorespiratory sleep studies (as possible with POLY-MESAM) are best limited to patients for whom the diagnosis of OSA is highly probable or as a follow-up tool in selected circumstances.
    Notes: Zusammenfassung Seit einigen Jahren sind 7kanalige Polygraphiegeräte in der ambulanten Vordiagnostik schlafbezogener Atmungsstörungen im Einsatz. Eines dieser Geräte ist das POLY-MESAM. Vorliegender 2. Teil der Studie beinhaltet die Validierung des Geräts. Die Ergebnisse der Polygraphie mit dem POLY-MESAM werden mit den Ergebnissen einer gleichzeitig durchgeführten 12-Kanal-Polysomnographie verglichen. Es wurden 49 Patienten beiderlei Geschlechts und mit unterschiedlichem Schweregrad einer obstruktiven Schlafapnoe unter stationären Bedingungen untersucht. Als Kriterium für eine manifeste Schlafapnoe wurde ein Apnoe-Hypopnoe-Index (AHI) von mehr als 15 festgesetzt. Der polysomnographisch ermittelte AHI wurde als Basiswert verwendet. Daran gemessen konnte für die ambulante POLY-MESAM-Messung eine Sensitivität von 86,4% und eine Spezifität von 100% für die Vorhersage einer manifesten Schlafapnoe ermittelt werden. Gemessen an den bisher validierten 4-Kanal-Geräten ist das POLY-MESAM damit vergleichbar zuverlässig und bietet zusätzlich die Möglichkeit, die unterschiedlichen Arten der Atmungsereignisse zu charakterisieren. Das POLY-MESAM ist somit eine sinnvolle Weiterentwicklung des MESAM4. In einigen Fällen kommt es dazu, daß POLY-MESAM den AHI unterschätzt und somit zu falsch-negativen Ergebnissen kommen kann. Daher kann das POLY-MESAM die komplette Polysomnographie als Standardverfahren nicht ersetzen.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1433-0458
    Keywords: Schlüsselwörter Schlafapnoe ; Ambulante Polygraphie ; POLY-MESAM ; Key words Sleep apnea ; Ambulatory recording units ; POLY-MESAM
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: For some time, the ambulatory diagnosis of sleep-related breathing disorders has included the use of seven-channel recording units. One such unit is the POLY-MESAM (MAP, Martinsried, FRG). The first part of the present study prospectively investigated the handling of the system for physicians and patients, its technical reliability, reliability of the software used and the results in comparison to handscoring. Methods: In all, 104 patients (95 males, 9 females) were studied for different severities of obstructive sleep-related breathing disorders. The first 51 patients were connected to the POLY-MESAM in the evening within the clinic. The patients then slept at home and returned the next day. Another 53 patients received only a short briefing in the clinic and connected themselves at home to the POLY-MESAM System. Each patient`s status was monitored by means of a visual analogue scale. Automatic evaluation of the data was compared with the results of manual scoring. Results: From the data recorded only 6% of the results were not usable. Patients acceptances of the system were very high (94.3%). On average each patient required 21 minutes for attaching and detatching the device. Scoring and instructing the patients required an average of 23 min. Regarding the apnea-hypopnea index (AHI), the correlation between automatic (AHI=11.1) and manual (AHI=11.3) evaluations was high. Analysis of snoring turned out to be insufficient. Conclusions: The POLY-MESAM proved to be reliable and user-friendly. Our findings show that the system can be recommended for outpatient screening of sleep-related breathing disorders, with patients able to manage the system without help. Validation by using simultaneous polysomnography is the subject of part two of the study.
    Notes: Zusammenfassung In der ambulanten Heimdiagnostik schlafbezogener Atmungsstörungen kommen seit einiger Zeit 7kanalige Geräte zum Einsatz. Ein solches Gerät ist das POLY-MESAM (Fa. MAP). Der vorliegende 1. Teil der Studie hat die Handhabung des Geräts für Arzt und Patient, die technische Belastbarkeit des Geräts und die Zuverlässigkeit der automatischen Auswertung durch die zugehörige Software vs. Handauswertung prospektiv untersucht. 104 Patienten beiderlei Geschlechts und mit unterschiedlichem Schweregrad einer obstruktiven Schlafapnoe wurden untersucht. Die ersten 51 Patienten wurden am Abend in der Klinik von 2 Ärzten an das POLY-MESAM-Gerät angeschlossen und über seine Funktionen unterrichtet. Die 2. Serie von 53 Patienten bekam am Nachmittag lediglich eine Einweisung in das POLY-MESAM-Gerät und hat den Anschluß zu Hause selbst vollzogen. Das Befinden der Patienten wurde mittels einer visuellen Analogskala festgehalten. Die automatische Auswertung wurde mit einer Handauswertung verglichen. Die Studie hat insgesamt knapp 6% unbrauchbare Ergebnisse erbracht. Die Akzeptanz des Geräts durch die Patienten ist mit bis zu 94,3% ausgesprochen hoch. Bezüglich des Apnoe-Hypopnoe-Indexes (AHI) ist die Korrelation zwischen automatischer (AHI=11,1) und Handauswertung (AHI=11,3) sehr gut. Das Gerät läßt sich aufgrund seiner soliden Bauart und Bedienungsfreundlichkeit sehr gut als ambulante Screeningmethode für obstruktive Schlafatmungsstörungen durch den Patienten selbst einsetzen. Validierungsuntersuchungen mittels simultaner Polysomnographie sind Gegenstand des 2. Teils der Studie.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...