Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Une méthode a été développée pour évaluer la sensitivité au taux du coeur S0 du système barorécepteur, qui est défini comme étant le ralentissement du taux du coeur pour chaque augmentation unitaire de la pression artérielle moyenne. Des valeurs moyennes pour le système intact, de l'ordre de 2,23 à 3,65 battements min−1 mmHg−1 ont été mesurées chez le chien et de 0,5 battements min−1 mmHg−1 chez un poney. Les barorécepteurs sinus carotides ajoutent une sensitivité considérable mais non prépondérante au système régulatoire cardiovasculaire, pour la pression sanguine. Des diminutions deS 0de l'ordre de 40% ont été observées lorsque ces récepteurs étaient essentiellement éliminés par l'occlusion des artères carotides. Le type d'anesthésie utilisé a une influence marquée sur la sensitivité du système barorécepteur, suggérant la possibilité d'utiliser ce coefficient de sensitivité pour évaluer l'influence des anesthésiques sur le mécanisme homéostatique pour la pression sanguine.
    Abstract: Inhaltsangabe Es wurde eine Methode zur Beurteilung der Herzfrequenzempfindlichkeit S0 des Baroreceptorsystems entwickelt, die als Herzfrequenzabnahme pro Einheitszunahme des mittleren Arteriendrucks definiert wird. Im Hund wurden für das Intaktsystem Durchschnittswerte im Bereich von 2,23–3,65 Schlägen min−1 mmHg−1 und in einem Pony 0,5 Schläge min−1 mmHg−1 festgestellt. Die Carotis-Sinus-Baroreceptoren tragen zu einer erheblich erhöhten Empfindlichkeit des kardiovaskulären Systems in bezug auf den Blutdruck bei, jedoch nicht in ausschlaggebendem Maße.S 0-Senkungen um ca. 40% wurden festgestellt, wenn diese Receptoren durch Okklusion der Carotis-Arterien im wesentlichen ausgeschaltet wurden. Die angewandte Anästhesiemethode hat einen bedeutenden Einfluß auf die Empfindlichkeit des Baroreceptorsystems, woraus geschlossen werden kann, daß dieser Empfindlich-keitskoeffizient möglicherweise zur Beurteilung des Einflusses von Anästhetica auf den homöostatischen Mechanismus in bezug auf den Blutdruck verwendet werden kann.
    Notes: Abstract A method has been developed to evaluate the heartrate sensitivity (S 0) of the baroreceptor system, which is defined as the decrease in heartrate per unit increase in mean arterial pressure. Average values, for the intact system, of the order of 2·23–3·65 beats min−1 mmHg−1 were found in the dog, and of 0·5 beats min−1 mmHg−1 in one pony. The carotid sinus baroreceptors add considerable, but not preponderant, sensitivity to the cardiovascular regulatory system for blood pressure. Decreases inS 0 of the order of 40% were found when these receptors were essentially eliminated by occlusion of the carotid arteries. The type of anaesthesia used has a marked influence on the sensitivity of the baroreceptor system, suggesting the possibility of using this sensitivity coefficient to evaluate the influence of anaesthetics on the homeostatic mechanisms for blood pressure.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Les pré-ventre ouvertr 0, pression de référencep 0 et taux cardiaquer 0 du système régulatoire de la pression sanguine ont été estimés sous quatre condition expérimentales différentes en employant un ballon aortique et en présumant un abordage théorique basé sur un modèle linéaire du premier ordre. Des valeurs moyennes de 1,7 à 3,7, 75 à 130 mmHg et 95 à 130 battements/minute furent obtenus respectivement pourg 0,p 0, etr 0. Des variations significatives de ces paramètres ont été observées lors du changement des conditions anesthésiques. Il est suggéré queg 0,p 0, etr 0 puissent avoir des applications cliniques pour la caractérisation à la fois des syndromes hypotensif et hypertensif et aussi pour l'évaluation des effets d'agents anesthésiques.
    Abstract: Inhaltsangabe Der offene schleifengewinng 0, der Bezugsdruckp 0 und die Basalherzfrequenzr 0 des blutdruckregelnden Systems wurden unter vier verschiedenen Versuchsbedingungen mit Hilfe eines Aortenballons geschätzt, wobei von einer auf ein lineares Modell erster Ordnung begründeten theoretischen Betrachtungsweise ausgegangen wurde. Fürg 0,p 0 undr 0 wurden Durchschnittswette von 1,7–3,7, bzw. 75–130 mmHg und 95–130 Schlägen/min ermittelt. Beträchtliche Schwankungen dieser Parameter wurden beobachtet, wenn die Anästhesieverhältnisse geändert wurden. Es wird vermutet, daßg 0,p 0 undr 0 sowohl bei der Charakterisierung hypotonischer und hypertonischer, Syndrome als auch bei der, Beurteilung der Wirkung von Anästhetica nützliche klinische Anwendungsmöglichkeiten bieten könnten.
    Notes: Abstract The open-loop gainG 0 reference pressureP 0 and basal heartrateR 0 of the blood-pressure regulatory system have been estimated under four different experimental conditions by employing an aortic balloon and assuming a theoretical approach based on a 1st-order linear model. Mean values of 1·7–3·7, 75–130 mmHg, and 95–130 beats/min were obtained forG 0,P 0 andR 0, respectively. Significant variations in these parameters were observed when the anaesthetic conditions were changed. It is suggested thatG 0,P 0 andR 0 may have useful clinical applications both in characterising hypotensive and hypertensive syndromes and also in assessing the effect of anaesthetic agents.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Une analyse mathématique de la variance du potential évoqué moyen comme fonction du nombre de stimulations présentées,N, est dérivée, sous condition que la réponse soit perturbée additivement par bruit de fond stationnaire. On compare la variance en cas de stimulation strictement périodique, et en case de stimulation aléatoire, c'est à dire, si les intervalles entre les stimulations varient selon une distribution Gaussienne. En outre, les intervalles peuvent être corrélés mutuellement, par example conformément un processus Markov-Gaussien. Il est déduit que par l'introduction d'une stimulation apériodique, en général, la relation entre la variance etN s'incline vers le cas d'un bruit de spectre à large bande, donc la variance ètant proportionale à 1/N.
    Abstract: Zusammenfassung Eine mathematische Analyse der Varianz des gemittelten evozierten Reaktions-potentiales als Funktion der Anzahl von angebotene ReizeN wird dargestellt, unter der Voraussetzung dass der evozierte Potential von additiven stationären Rauschen gestört wird. Es werden verglichen die Varianz wenn die Reize rein periodisch erfolgen und wenn die Zeitintervalle zwischen Reize normal verteilte Schwankungen unterworfen sind. Im letzten Falle dürfen die Zeitintervalle wechselseitig korreliert sein, z.B. gemäss einem Gausschen Markov Prozess. Es wird gezeigt dass im Allgemeinen bei der Einführung von aperiodische Reizfolgen das Funktionalverband zwischen Varianz undN sich dem Falle zustrebt wenn Rauschen mit breitbandigem Leistungsspektrum vorliegt, wobei also die Varianz proportional zu 1/N ist.
    Notes: Abstract A mathematical analysis of the variance of the average evoked-response computation as a function of the numberN of stimuli presented is made for the case when the response is disturbed by additive stationary noise. A comparison is made between the variance for purely periodic stimuli and that for stimuli of which the interstimulus durations are Gaussian distributed. In the latter situation, the interval durations may be correlated with each other, e.g. according to a Gaussian Markov process. It is deduced that, in general, the introduction of aperiodic stimulation tends to make the functional relationship between the variance andN behave as though it holds for noise with a very broad frequency spectrum; the variance is proportional to 1/N.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire L'article discute les problèmes techniques, les pièges et les artefacts ayant été rencontrés lors de l'examen du balayage ultrasonique B. L'expérience des auteurs se rapporte à des travaux entrepris durant les trois dernières années, faisant usage du Diasonographe, mais la plupart des commentaires peuvent aussi être appliqués à d'autres machines sur le marché. Une connaissance de ces problèmes est essentielle afin d'obtenir la valeur diagnostique complète de cet examen.
    Abstract: Inhaltsangabe Die Abhandlung befaßt sich mit den technischen Problemen, Fehlern und Geistern, die bei Ultraschall-B Scan-Untersuchungen aufgetreten sind. Die Erfahrungen des Autors beziehen sich auf Arbeiten während der letzten drei Jahre unter Benutzung des Diasonographen, jedoch lassen sich die meisten Bemerkungen auch auf andere handelsübliche Maschinen anwenden. Wenn die Untersuchung von vollem diagnostischem Wert sein soll, ist eine Kenntnis dieser Probleme unerläßlich.
    Notes: Abstract The paper discusses the technical problems, pitfalls and artefacts that we have encountered during ultrasonic B scan examination. Our experience relates to work carried out over the last three years using the Diasonograph, but most of the comments may also be applied to other machines on the market. A knowledge of these problems is essential if the full diagnostic value is to be obtained from the examination.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Les auteurs décrivent la construction et le procédé pour l'insertion d'une électrode flexible mise au point afin de surmonter le problème de dislocation. Le bout creux de l'électrode contient un écrou mobile portant des crochets en platine iridié pour la fixation myocardiale; les crochets sont commandés par un stylet passant à travers la connexion creuse entre le bout d'électrode et le noeud sinusal de Keith et Flack. Les résultats d'expériments sur animaux et les mesures de variation de durée de seuil de stimulation sont résumés.
    Abstract: Inhaltsangabe Die Autoren beschreiben die Herstellung und Einführung einer flexiblen Elektrode, die entwickelt wurde, um das Verlagerungsproblem zu beseitigen. Die hohle Elektrodenspitze enthält einen beweglichen Bolzen, welcher Platin-Iridium-Haken für eine myokardiale Befestigung trägt; die Haken werden von einer Sonde, die durch die hohle Verbindung zwischen der Elektrodenspitze und dem Schrittmacher führt, bewegt. Ergebnisse von Tierexperimenten und zeitvariablen Messungen der Stimulationsschwelle werden kurz zusammengefasst.
    Notes: Abstract The authors describe the construction and procedure for insertion of a flexible electrode designed to overcome the problem of dislocation. The hollow electrode tip contains a movable bolt which carries platinum-iridium hooks for myocardial fixation; the hooks are actuated by a stylet passing through the hollow connection between electrode tip and pacemaker. Results of animal experiments and time-variation measurements of the stimulation threshold are summarised.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Description / Table of Contents: Sommaire Nous avons fait l'analyse mathématique de l'hémodialyse d'un système à 3 compartiments (extravasculaire, intravasculaire, produit de dialyse). Nous avons concentré notre attention sur l'usage des dialyseurs à contre-courant à passage unique, du fait que les recherches précédentes avaient caractérisé la constante de transfer entre les compartiments intravasculaire et produit de dialyse de ces dialyseurs. La théorie a été verifiée par étudesin vivo sur des chiens néphrectomisés avec du sodium étiqueté. Au cas ou le procédé d'hémodialyse serait mis sur ordinateur et automatisé, ces travaux peuvent former la base de la prédiction des concentrations, espaces libres, et espaces de distribution pour use substance donnée à tout instant.
    Abstract: Inhaltsangabe Die Hämodialyse eines 3-teiligen Systems (extravaskulär, intravaskulär, Dialysat) wurde mathematisch analysiert. Die Aufmerksamkeit konzentrierte sich auf den Gebrauch von Gegenstrom-Dialysatoren mit einmaligem Durchgang, da die Übertragungskonstante zwischen dem intravaskulären Abschnitt und dem Dialysatsabschnitt in diesen Dialysatoren bereits in früheren Untersuchungen charakterisiert wurde. Die Theorie wurde mit Hilfe vonin vivo Studien mit beschriftetem Natrium in nephrektomierten Hunden nachgewiesen. Wenn das Hämodialyseverfahren in einen Computer aufgenommen und automatisiert wird, kann diese Arbeit jederzeit die Grundlage für die Voraussage von Konzentrationen, Clearance-Werten und Verteilungsabständen für einen gegebenen Stoff bilden.
    Notes: Abstract Haemodialysis of a 3-compartment system (extravascular, intravascular, dialysate) was analysed mathematically. Attention was concentrated on the use of single-pass counterflow dialysers since previous investigations had characterised the transfer constant between the intravascular and dialysate compartments in these dialysers. The theory was verified usingin vivo studies with labelled sodium in nephrectomised dogs. In the event that the hemodialysis procedure may be computerised and automised, this work may form the basis for the prediction of concentrations, clearances and distribution spaces for a given substance at any time.
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1741-0444
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Type of Medium: Electronic Resource
    Signatur Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...